6) Disconnect the gear motor wiring, then remove the gear motor.
7) Remove the gear motor bracket and spline coupling from the old gear motor and place
on the new gear motor.
8) Install the new gear motor and reconnect the electrical wires.
9) Replace the removed parts in the reverse order of which they were removed.
10) Replace the top and side panels in their correct positions.
11) Move the control switch to the "ICE" position.
12) Plug the unit into the electrical outlet, then move the power switch to the "ON" position
to start the automatic icemaking process.
13) Replace the front panel in its correct position.