Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC2 (Mech. Stand-Alone) Shutdown Initiation Delay (S1 dip switch 8)
- 7. BC2 (Mech. Stand-Alone) Shutdown Time (S1 Dip Switch 9)
- 8. Factory Use (S1 Dip Switch 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-450MAJ
- 15b. F-450MAJ-C
- 16a. F-801MAJ
- 16b. F-801MAJ-C
- 17a. F-801MWJ
- 17b. F-801MWJ-C
- 18a. F-1001MAJ
- 18b. F-1001MAJ-C
- 19a. F-1001MWJ
- 19b. F-1001MWJ-C
- 20a. F-1001MRJ
- 20b. F-1001MRJ-C
- 21a. F-1001MLJ
- 21b. F-1002MLJ
- 22a. F-1002MAJ
- 22b. F-1002MAJ-C
- 23a. F-1002MWJ
- 23b. F-1002MWJ-C
- 24a. F-1002MRJ
- 24b. F-1002MRJ-C
- 25a. F-1501MAJ
- 25b. F-1501MAJ-C
- 26a. F-1501MWJ
- 26b. F-1501MWJ-C
- 27a. F-1501MRJ
- 27b. F-1501MRJ-C
- 28a. F-2001MLJ
- 28b. F-2001MWJ
- 28c. F-2001MRJ
- 28d. F-2001MRJ-C
- 28e. F-2001MRJ3
- 29. FD-650MAJ-C
- 30. FD-650MWJ-C
- 31. FD-650MRJ-C
- 32. FD-1001MAJ-C
- 33. FD-1001MRJ-C
- 34. FD-1002MAJ-C
- 35. FD-1002MRJ-C
- B. Wiring Diagrams
- 1. F-1001MAH(-C), F-1001MWH(-C), F-1001MRH(-C), FD-1001M_H-C
- 2. F-1501M_H(-C)
- 3. F-2001MWH(-C), F-2001MRH(-C)(3), F-2001MWJ, F-2001MRJ(-C)(3)
- 4. F-1001MLJ, F-1002MLJ, F-2001MLH, F-2001MLJ
- 5. FD-650M_H-C
- 6. F-450MAJ(-C)
- 7. F-801M_J(-C)
- 8. F-1001MAJ(-C), F-1001MWJ(-C), F-1001MRJ(-C)
- 9. F-1002MAJ(-C), F-1002MWJ(-C), F-1002MRJ(-C), FD-1002M_J-C
- 10. F-1501M_J(-C)
- 11. FD-650M_J(-C)
- 12. FD-1001M_J-C
- A. Specification & Performance Data Sheets
44
5. Bin Control Selector (S1 dip switch 7)
The bin control is factory set. No adjustment required. WARNING! Do not place
S1 dip switch 7 in the "OFF" position on dispenser unit applications. This could
lead to icemaker movement or ice overow.
S1 Dip Switch
Setting
Bin Control Application Gear Motor Delay
No. 7
OFF BC2 (mechanical stand-alone) (Standard Ice Storage Bins Only) 5 seconds
ON
BC1 (infrared sensor) Stand-Alone and
BC1 (infrared sensor) with BC2 (mechanical backup)
30 seconds
6. BC2 (Mech. Stand-Alone) Shutdown Initiation Delay (S1 dip switch 8)
Only available when S1 dip switch 7 is in the "OFF" position. Factory set for normal
operation. No adjustment is required. The shutdown initiation delay is the time between
the mechanical bin control opening and dip switch 9 timer starting.
S1 Dip Switch
Setting
Shutdown Delay
No. 8
OFF 0.25 Seconds
ON 6.7 Seconds
7. BC2 (Mech. Stand-Alone) Shutdown Time (S1 Dip Switch 9)
Only available when S1 dip switch 7 is in the "OFF" position. Factory set for optimum
performance. Do not adjust. Dip switch 9 shutdown timing starts when Dip Switch 8 timer
terminates.
S1 Dip Switch
Setting
Shutdown Sequence
No. 9
OFF
Slow timing (90s after dip switch 8 timer terminates, the COMP shuts down; 60 sec.
later, the GM shuts down)
ON
Fast timing (immediate)(after dip switch 8 timer terminates, both COMP & GM shuts
down at the same time)
8. Factory Use (S1 Dip Switch 10)
Factory set for optimum performance. Do not adjust.