Service Manual

Table Of Contents
113
30. FD-650MWJ-C
Specification Shee
t
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
7.9
A
MINIMUM CIRCUIT AMPACITY
20
A
MAXIMUM FUSE SIZE
20
A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W
(
kWH/100 lbs.
)
866
(
4.02
)
869
(
3.35
)
POTABLE WATER 62
(
12.0
)
107
(
12.0
)
g
al./24HR
(g
al./100 lbs.
)
WATER-COOLED CONDENSER 496
(
95.3
)
394
(
63.3
)
g
al./24HR
(g
al./100 lbs.
)
SHAPE OF ICE Cubele
t
ICE HARDNESS A
pp
rox. 91.0%, Ice
(
32/21
(
90/70
)
, Conductivit
y
200
µ
s/cm
)
BIN CONTROL SYSTEM
Photoelectric Senso
r
REFRIGERANT CHARGE R404A, 0 lb. 15 oz.
(
425
g)
APPROXIMATE Ambien
t
ICE PRODUCTION Tem
p
. °F
(
°C
)
PER 24 HR.
70 (21)
622
(
282
)
614
(
279
)
595
(
270
)
80 (26)
577
(
262
)
559
(
254
)
542
(
246
)
90 (32)
525
(
238
)
520
(
236
)
493
(
224
)
lbs./day ( kg/day)
100 (38)
478 ( 217 ) 463 ( 210 )
437
( 198 )
APPROXIMATE ELECTRIC
70 (21)
869
-- 868 -- 868 --
CONSUMPTION
80 (26)
868 -- 867 -- 867 --
90 (32)
866 --
866
-- 870 --
watts
100 (38)
874 -- 878 --
881
--
APPROXIMATE WATER
70 (21)
398
( 1508 ) 707 ( 2676 ) 1651 ( 6248 )
CONSUMPTION PER 24 HR.
80 (26)
393 ( 1488 ) 700 ( 2651 ) 1644 ( 6224 )
(TOTAL)
90 (32)
387 ( 1464 )
696
( 2633 ) 1639 ( 6202 )
gal. / day (l/day)
100 (38)
381 ( 1443 ) 689 ( 2607 )
1632
( 6176 )
EVAPORATOR OUTLET TEMP.
70 (21)
17
( (-8) ) 17 ( (-8) ) 17 ( (-8) )
°F (°C)
80 (26)
18 ( (-8) ) 18 ( (-8) ) 18 ( (-8) )
90 (32)
19 ( (-7) )
19
( (-7) ) 19 ( (-7) )
100 (38)
20 ( (-7) ) 20 ( (-6) )
21
( (-6) )
HEAD PRESSURE
70 (21)
267
( 18.8 ) 267 ( 18.8 ) 267 ( 18.8 )
80 (26)
267 ( 18.8 ) 268 ( 18.8 ) 268 ( 18.8 )
90 (32)
268 ( 18.8 )
268
( 18.9 ) 272 ( 19.1 )
PSIG
(
k
g
/cm
2
G
)
100 (38)
276 ( 19.4 ) 279 ( 19.6 )
283
( 19.9 )
SUCTION PRESSURE
70 (21)
42
( 3.0 ) 42 ( 3.0 ) 43 ( 3.0 )
PSIG
(
k
g
/cm
2
G
)
80 (26)
43 ( 3.0 ) 43 ( 3.0 ) 43 ( 3.0 )
90 (32)
44 ( 3.1 )
44
( 3.1 ) 44 ( 3.1 )
100 (38)
45 ( 3.1 ) 45 ( 3.2 ) *
46
( 3.2 )
26 gal/h (AT 90°F / WT 70°F)
Less than 7 PSIG
BTU/h (AT 90°F / WT 70°F)
BTU/h (AT 90°F / WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 800
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM CONDENSER 5,400
Performance Shee
t
Water Temp. °F (°C)
50 (10) 70 (21) 90 (32)
WATER FLOW FOR CONDENSER
ENG F-013.0.1196