37
e) Turn on the power supply to start the automatic icemaking process. WARNING!Keep
hands, hair, and loose clothing clear of the cutter on top of the evaporator
assembly. Allow the icemaker to run until the compressor starts (approximately
60seconds).
f) Press and hold the actuator paddle located in the top of the chute. The icemaker
should shut down within 6seconds.
g) Move the power switch to the "OFF" position, then turn off the power supply.
h) Replace the chute assembly and strap in their correct positions.
i) Move the power switch to the "ON" position.
j) Replace the top and front panels in their correct positions.
10) Pour warm water into the dispenser unit/ice storage bin and melt any remaining ice.
Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
11) Turn on the power supply to start the automatic icemaking process.
12) On water-cooled models, conrm proper condenser drain outlet/return outlet
temperature as outlined in "II.F.2. Water-Cooled Condenser."