Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- A. Construction
- B. Icemaking Unit
- C. Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- A. Sequence of Operation Flow Chart
- 1. Icemaking and Drain Cycle
- 2. Shutdown
- B. Service Diagnosis
- 1. Ice Production Check
- 2. Diagnostic Procedure
- C. Control Board Check
- D. Bin Control Check
- E. Float Switch Check and Cleaning
- F. Diagnostic Tables
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3).
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. Agitation and Ice Purge Timer (S1 dip switch 8)
- 7. Mechanical Shutdown Delay (S1 dip switch 9)
- 8. Factory Use (S1 Dip Switch 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- A. Refrigeration Circuit Service Information
- B. Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1. F-300BAJ
- 2. F-500BAJ
- B. Wiring Diagrams
- 1. F-300BAJ
- 2. F-500BAJ
15
6) Startup–CB "POWER OK" LED is on. Plug the appliance into the electrical outlet
(F-300BAJ) or turn on the power supply (F-500BAJ), then move the power switch to the
"ON" position. Make sure the control switch is in the "ICE" position.
CB "POWER OK" LED turns on.
Diagnosis CB "POWER OK" LED: Check that CB "POWER OK" LED is on. Ifnot,
check for 115VAC at control transformer black (BK) wire to neutral (W). If 115VAC is not
present, check the power switch, power supply cord, and breaker. If 115VAC is present,
check control transformer continuity. Replace as needed. Next, check for 24VAC at
control transformer red (R) wire to neutral (LBU). If 24VAC is not present, check control
transformer continuity. Replace as needed. If24VAC is present, check 24VAC 1A fuse.
If fuse is good, check for 24VAC at CB K8 #1 (W/R) to CB K8 #2 (LBU). If 24VAC is
present and "POWER OK" LED is off, replace CB.
Diagnosis BC: Check that the actuator paddle is properly positioned. Check continuity
across BC. If open, replace BC. Next, check VDC at CB K8#3(GY) to CB K8 #4 (GY).
When BC is closed 0VDC is read. Move the actuator paddle to open BC(2). When open,
5VDCis present between CB K8 #3 (GY) and CB K8#4(GY). If 5VDC is not present
when BC is open, replace CB. Return actuator to its normal position.
7) Fill Cycle – "WTRIN" LED is on. Reservoir is empty and LFS and UFS are open.
90-sec. FT starts. WV energizes and ll cycle starts. LFS closes. Nothing occurs at this
time. Reservoir continues to ll until UFS closes. When UFS closes, WV de-energizes,
90-sec. FT is terminated, and CB "WTRIN" LED turns off. 30-min. FZTand 5-sec.
GM delay timer start. IfUFS remains open longer than 90 sec. after LFS opens,
FTexceeded and CB sounds a 1-beep alarm. WVremains energized until UFS closes.
Alarm resets automatically when UFS closes. Diagnosis: If reservoir is empty and
"WTRIN" LED is off, conrm LFS status. See "II.E. Float Switch Check and Cleaning."
IfLFS is open and "WTRIN" LED is off, replace CB. If "WTRIN" LED is on, check
that the reservoir lls. If not, check water supply line shut-off valve, water lters, and
WVscreen. If "WTRIN" LED is on and WV is off, check CB K2 #8(O) to a neutral
(LBU) for 24VAC. If24VAC is not present, check CB K2 #9(W/R) to a neutral (LBU) for
24VAC. If 24VAC is present on CB K2 #9(W/R)and not on CB K2 #8 (O), replace CB.
If 24VAC is present on CB K2 #8(O), check continuity through WV solenoid. If open,
replace WV. If WV is energized and rell exceeds FT with no water in the reservoir,
check for DV leaking. Ifreservoir is full and overowing check for open UFS. See "II.E
Float Switch Check and Cleaning." If UFS is closed, check that WV de-energizes. If
not, check CB K2 #8 (O) to a neutral (LBU) for 24VAC. If 24VAC is present, replace CB.
IfWV de-energizes and water continues to ll the reservoir, replace WV.