Instructions Manual

7
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel.
For certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. F-300BAJ
Model Number F-300BAJ
AC Supply Voltage 115/60/1
Amperes 7.8 AMPS
Design Pressure HI-467PSI LO-250PSI
Refrigerant 404A 9.17 OZ.
2. F-500BAJ
Model Number F-500BAJ
AC Supply Voltage 115/60/1
Compressor 115V 10.5RLA 54.5LRA
Gear Motor 115V 2.4FLA 1/4 HP
Fan 115V 0.85A MAX
Other 115V 0.08A
Maximum Fuse Size 20 AMPS
Max. HACR Circuit Breaker (USA only) 20 AMPS
Max. Circuit Breaker (Canada only) 20 AMPS
Minimum Circuit Ampacity 20 AMPS
Design Pressure HI-467PSI LO-250PSI
Refrigerant 404A 1 LB. 0.6 OZ.