IV. Preparing the Appliance for Periods of Non-Use
NOTICE
When storing the appliance for an extended time or in sub-freezing temperatures,
follow the instructions below to prevent damage.
When the appliance is not used for two or three days under normal conditions, it
is sufficient to only move the power switch to the "OFF" position. When storing the
appliance for extended time or in sub-freezing temperatures, follow the instructions
below.
1) Close the icemaker water supply line shut-off valve and open the icemaker water supply
line drain valve.
2) Remove the top and front panels.
3) Move the power switch to the "OFF" position, then move the control switch to the
"DRAIN" position. Next, move the power switch to the "ON" position. Replace the front
and top panels in their correct positions. Allow the water system to drain for 5 min.
Note: If the control switch is left in the "DRAIN" position for 10 min. or more, a 2-beep
alarm sounds every 5 sec. Move the control switch out of the "DRAIN" position to
clear the alarm.
4) Attach a compressed air or carbon dioxide supply to the icemaker water supply line
drain valve.
5) Move the control switch to the "ICE" position, to open the inlet water valve and briey
blow out the inlet water valve. After blowing out the inlet water valve, move the power
switch to the "OFF" position.
6) Close the icemaker water supply line drain valve.
7) Remove all ice from the ice storage bin. Clean the ice storage bin liner and door using a
neutral cleaner. Rinse thoroughly after cleaning.
8) Replace the top and front panels in their correct positions.