23
B. Cleaning and Sanitizing Instructions
The icemaker must be cleaned and sanitized at least twice a year. More frequent
cleaning and sanitizing may be required insome conditions.
WARNING
• To prevent injury to individuals and damage to the appliance, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the cleaning and sanitizing
solutions.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
• After cleaning and sanitizing, do not use ice made from the cleaning and
sanitizing solutions. Be careful not to leave any solution on the parts or in the ice
storage bin.
• Do not place ngers or any other objects into the ice discharge opening.
1. Cleaning Solution
Dilute 4.8 . oz. (142 ml) of Hoshizaki "Scale Away" with 0.8 gal. (3 l) of warm water. This
is a minimum amount. Make more solution if necessary. IMPORTANT! For safety and
maximum effectiveness, use the solution immediately after dilution.
2. Cleaning Procedure
1) Close the water supply line shut-off valve.
2) Remove the top and front panels.
3) Move the power switch to the "OFF" position, then move the control switch to the
"DRAIN" position. Next, move the power switch to the "ON" position. Replace the front
and top panels in their correct positions. Allow the water system to drain for 5 min.
Note: If the control switch is left in the "DRAIN" position for 10 min. or more, a 2-beep
alarm sounds every 5 sec. Move the control switch out of the "DRAIN" position to
clear the alarm.
4) Remove all ice from the ice storage bin.
5) After the water system has drained, remove the top and front panels, then move the
power switch to the "OFF" position.
6) Remove spout B and gasket B, then remove spout A, and gasket A. See Fig. 8.
7) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to run through the overow hose on the
reservoir.
Note: If there is excess scale on the extruding head, ll the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block ow. Pour additional cleaning
solution over the extruding head until the evaporator assembly is completely full.
8) Replace gasket A, spout A, gasket B, and spout B in their correct positions.