12
E. Electrical Connection
WARNING
• Electrical connection must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could result in death,
electric shock, serious injury, re, or damage.
• The appliance requires an independent power supply of proper capacity. See
the nameplate for electrical specications. Failure to use an independent power
supply of proper capacity can result in a tripped breaker, blown fuse, damage to
existing wiring, or component failure. This could lead to heat generation or re.
• THE APPLIANCE MUST BE GROUNDED:
Failure to properly ground the
appliance may result in death, electric shock, or re.
• To reduce the risk of electric shock, do not touch the power switch, control switch,
or plug (on corded models) with damp hands.
• For Corded Models
• This appliance is equipped with a NEMA5-15 three-prong grounding plug
to
reduce the risk of potential shock hazards. Corded models must be plugged into
a properly grounded, independent 3-prong wall outlet. Ifthe outlet is a 2-prong
outlet, it is your personal responsibility to have a qualied electrician replace it
with a properly grounded, independent 3-prong wall outlet. Do not remove the
ground prong from the plug and do not use an adapter plug. Failure to follow these
instuctions may result in death, electric shock, or re.
• Do not use an extension cord.
• Make sure the power switch is in the "OFF" position before plugging in or
unplugging the appliance to reduce the risk of electric shock.
• Do not use an appliance with a damaged power cord. The power cord should not
be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could
result in electric shock or re. To unplug the appliance, be sure to pull the plug, not
the cord, and do not jerk the cord.
• The GREEN ground wire in the factory-installed power cord is connected to the
appliance. If it becomes necessary to remove or replace the power cord, be sure to
connect the power cord's ground wire to this screw upon reattachment.
• For Hard-Wired Models
• Electrical connection must be hard-wired.
• Electrical connections must be made in accordance with the instructions on the
"WARNING" tag, provided with the pig tail leads on the junction box. See Fig. 3.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.