Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- A. Construction
- B. Icemaking Unit
- C. Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- A. Sequence of Operation Flow Chart
- 1. Icemaking and Drain Cycle
- 2. Shutdown
- B. Service Diagnosis
- 1. Ice Production Check
- 2. Diagnostic Procedure
- C. Control Board Check
- D. Bin Control Check
- E. Float Switch Check and Cleaning
- F. Diagnostic Tables
- III. Controls and Adjustments
- A. Control Board
- 1. Control Board Layout Shown:
- 2. LED Lights and Audible Alarm Safeties
- 3. Ice Purge Cycle Bypass
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6a. Mechanical Shutdown Delay (S1 dip switch 8) Auxiliary Code E-0:
- 6b. Agitation and Ice Purge Timer (S1 dip switch 8) Auxiliary Code F-0 and Later:
- 7. Mechanical Shutdown Delay (S1 dip switch 9) Auxiliary Code F-0 and Later
- 8a. Factory Use (S1 Dip Switch 9 & 10) Auxiliary Code E-0
- 8b. Factory Use (S1 Dip Switch 10) Auxiliary Code F-0 and Later
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- A. Refrigeration Circuit Service Information
- B. Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1. F-330BAJ
- 2. F-330BAJ-C
- B. Wiring Diagram
15
8) Ice Purge Cycle – "GM" LED is on. 5-sec. GM delay timer terminates. GM,
CCR, FM, and EH (-C model) energize. Once CCR energizes, 5VDC circuit closes
through CCR terminal #3 (W/O) and terminal #5 (W/O) and CB K9 #5 (W/O) and
K9 #6 (W/O). After 5VDC circuit closes, 5-min. ice purge timer starts. Tobypass the
5-min. Ice Purge Cycle, press the "SERVICE" button on CB after the "GM" LED turns
on. WARNING! Risk of electric shock. Care should be taken not to touch live
terminals. Diagnosis: If "GM" LED is off, check that UFS closes and WV de-energizes.
IfUFS is closed, 30 sec. has passed, and "GM" LED remains off, replace CB. If"GM"
LED is on and GM is off, check CB K1 #2 (BK) to a neutral (W) for 115VAC. If115VAC is
not present, check 115VAC power supply. If115VAC is present, check CB K1 #3(P) to
a neutral (W). If 115VAC is present on CB K1 #2 (BK) and not on CB K1 #3 (P), replace
CB. If115VAC is present on CB K1#3 (P), check GM fuse, GM internal protector,
GM windings and capacitor, and GM coupling between auger and GM. When GM
energizes, CCR energizes starting 5-min. ice purge timer. If FM does not start, check
FM capacitor, FM windings, and FM bearings.
9) Freeze Cycle – "COMP" and "GM" LEDs are on. The 5-min. ice purge timer
terminates. GM, EH (-C model), CCR, and FM continue. Comp energizes. Ice
production starts 4to 6 min. after Comp energizes depending on ambient and water
conditions. As ice is produced, the water level in the reservoir drops. UFS opens.
Nothing happens at this time. When LFS opens, WV energizes and rell cycle begins,
FZT terminates, and FTstarts.
FZT: 30-Min. Freeze Safety Timer – FZT starts when UFS closes and terminates
when LFS opens. If LFS does not open within 30 min. of UFS closing, CB shuts down
the icemaker and sounds a 5-beep alarm. See "III.A.2.LED Lights and Audible Alarm
Safeties." To reset, turn the power supply off and on again. See "II.F. Diagnostic Tables"
for troubleshooting details.
Icemaker Diagnosis (CCR): 5-min. ice purge timer terminates, CB "COMP" LED is on
and COMP energizes. If not, check for 5VDC between CB K5 connector pin closest
to CB K4 connector and CB K9connector #5(W/O). If 5VDC is not present, replace
CB. If 5VDC is present, check for 5VDC between CB K5 connector pin closest to CB
K4 connector and CB K9connector #6(W/O). If 5VDC is present and CB "Comp"
LED is off (CR or COMP not energized), replace CB. If 5VDC is not present, check for
115VAC between CCR terminal #7(O) to CCR terminal #8(W) for 115VAC. If115VAC
is not present (GM not energized), see step 8 above. If 115VAC is present and CCR
contacts are open (5VDCpresent between terminals #3(W/O) and #5(W/O)), check
CCR solenoid voltage and solenoid continuity. Replace CCR if necessary.
Icemaker Diagnosis (COMP): If"COMP" LED is on and COMP is not energized,
check CB X1 relay BK wire to a neutral (W) and CB X1 relay V wire to a neutral (W) for
115VAC. If115VAC is present on CB X1BK wire and not on CBX1 V wire, replace CB.
If115VAC is present on CBX1V wire and COMP is not energized, check for 115VAC
at CB X1 Comp relay. Check Comp internal overload (motor protector), start relay, and
capacitors.