G. Final Checklist
WARNING
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after installation. Make sure that none have fallen into the ice
storage bin.
1) Have the legs been properly installed? Is the appliance level?
2) Is the appliance in a site where the ambient temperature is within 45°F to 100°F (7°C to
38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around?
3) Is there at least 24" (61 cm) at the top of the appliance for maintenance and service?
4) Have the shipping carton, tape, and packing material been removed from the
appliance?
5) Have all electrical and water connections been made? Do electrical and water
connections meet all national, state, and local code and regulation requirements?
6) Has the power supply voltage been checked or tested against the nameplate rating? Is
the power supply a properly grounded, independent 3-prong wall outlet?
7) Are the water supply and drain lines sized as specied? Are the water supply line
shut-off valve and drain valve installed? Has the water supply pressure been checked to
ensure a minimum of 10 PSIG and a maximum of 113 PSIG?
8) Is the compressor snug on all mounting pads? Have the refrigerant lines been checked
to make sure they do not rub or touch other lines or surfaces? Has the fan blade been
checked to make sure it turns freely?
9) Has the end user been given the instruction manual, and instructed on how to operate
the appliance and the importance of the recommended periodic maintenance?
10) Has the end user been given the name and telephone number of an authorized service
agent?
11) Has the warranty card been lled out and forwarded to the factory for warranty
registration?