J. Alarm Safeties
Should an alarm occur, follow the instructions in the table below to address the alarm. If
an alarm continues to occur, contact an authorized service agent.
WARNING
• Only qualied service technicians should service the appliance.
• To reduce the risk of electric shock, do not touch the icemaker power switch, control
switch, or plug with damp hands.
• Before Servicing: Move the icemaker's power switch to the "OFF" position, then
unplug the appliance.
No. of Beeps
(every 5 sec.)
Type of Alarm Reset Options
1 Low Water Safety
UFS open>90 sec. after WV energized.
Automatic reset once water supply is restored
and UFS closes.
2 Control Switch
In "DRAIN" position longer than 15 min.
Automatic reset once the control switch is
moved to the "ICE" position.
3 High-Pressure Switch
First and second activation in 1 hr.
Automatic reset once pressure drops below
the high pressure threshold and the high
pressure switch closes.
4 High-Pressure Switch
Third activation in 1 hr.
Call for service. To avoid possible catastrophic
failure, it is recommended to leave the
icemaker off until this alarm is resolved.
Manual reset. Turn power off and on again.
5 Freeze Timer
WV off>30 min. since last WV activation.
Manual reset. Turn power off and on again.
6 Low Voltage
92VAC±5% or less
"POWER OK" LED turns off if voltage
protection operates.
The control voltage safeties automatically
reset when voltage is corrected.
7 High Voltage
147VAC±5% or more
8 Gear Motor
CCR contacts fail to close.
Manual reset. Turn power off and on again.
9 Infrared Sensor (CB S1 dip switch 7 on)
MBC actuator paddle engaged.
Manual reset. Turn power off and on again.
Legend: CB–control board; CCR–compressor control relay; MBC–mechanical bin control;
UFS–upper oat switch; WV–inlet water valve