Specifications Sheet

Modular Flaker Ice Machine
Item #:
Project:
Qty:
AIA#:
618 Hwy, 74 S., Peachtree City, GA 30269 | TEL 800-438-6087 | FAX 800-345-1325 | www.hoshizakiamerica.com
© HOSHIZAKI AMERICA, INC.
Cube Dimensions*
* approximate size in inches, image not to scale
Features
• Up to 2280 lbs. of ice production per 24 hours
• Mount two units, side-by-side, in only 60” of floor
space for double the amount of ice production
• 2 second flush cycle every hour
• Flush cycle removes sediment for cleaner ice
• Protected by H-GUARD Plus
Antimicrobial Agent
• Nitrogen holding charge
• Can be used with refrigerant R404A, R407A, and
R407F
Durable stainless steel exterior
Advanced CleanCycle24
TM
design
Stainless steel auger with greaseless
bearing
Available on Bins:
• Ambient Temp Range 45 - 100°F
• Water Temp Range 45 - 90°F
• Water Pressure 10 - 113 PSIG
• Voltage Range 104-127V
Operating Limits
Icemaker Water Supply Line: Minimum 1/4” Nominal ID
Copper Water Tubing or Equivalent
Icemaker Drain Line: Minimum 3/4” Nominal ID Hard Pipe
or Equivalent
Plumbing
• Panels easily removed and all components
accessible for service.
• Allow 6” (15 cm) clearance at rear and sides for proper
air circulation and ease of maintenance/service. Allow
24” (61 cm) clearance at top to allow removal of auger.
Service
W x D x H
Hoshizaki reserves the right to change specifications without notice.
Printed in the U.S.A.
3 Year Parts & Labor on entire machine. 5 Year Parts on Compressor; air-cooled
condenser coil. Valid in United States, Canada, Puerto Rico and U.S. Territories.
Contact factory for warranty in other countries.
Warranty:
F-2001MLJ
F-2001MLJ
07/24/17
Item # 13155
Low-Side Series
B-250PF
B-500PF/SF
B-900PF/SF
B-1150SS
1”
Flaked
TM
30" x 27
1/2
" x 34
7/16
"*
B-700PF/SF
B-800PF/SF
F-2001MLJ*
Flaker Shown on
optional bin B-900
*Requires a rack system
for installation
Air / Water Temp
Lbs. per 24 hours
Condenser
Model
70°/ 50°F 90°/ 70°F
ICE PRODUCTION
Type of Ice
(Hardness Rating)
Potable
Gal. per 100 lbs.
Condenser
Gal. per 100 lbs.
Max. Fuse Size
or HACR
Circuit Breaker
Heat
Rejection
BTU/hr.
Shipping
Weight
Voltage
ENERGY
STAR
®
WATER USAGE
90°/ 70°F 90°/ 70°F
ELECTRICAL
90°/ 70°F
kWh Used
per 100 lbs.
Amperage
2280
F-2001MLJ
1733
Air-Cooled
Flaked (69.2) 12.0 N/A
0.6 15A 6.1A 115V/60/1 11,600
250 lbs.
B-1300SS
B-1500SS*
B-1650SS*
Top kit may be required. See Bin Spec Sheets. *Two unit application only.