Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
88
B. Wiring Diagrams
1. F-1001M_H(-C), FD-1001M_H-C
(BR)
(W)
(DBU)
INFRARED
SENSOR
(BK)
WIRE COLOR CODE
BK -BLACK
BR -BROWN
BU -BLUE
DBU -DARK BLUE
GR -GREEN
GY -GRAY
LBU -LIGHT BLUE
O -ORANGE
P -PINK
R -RED
V -VIOLET
W -WHITE
Y -YELLOW
W/BK -WHITE BLACK
W/BR -WHITE BROWN
W/BU -WHITE BLUE
W/O -WHITE ORANGE
W/R -WHITE RED
(T2)
(C)
N
W/O
W/O
O
CAP.
24MFD
GND
S2
S1
X1
115VAC
K9
5VDC
K5
K4
K3
J2
(C)
FUSE (1A)
FUSE
(3A)
L1
W/R
R
LBU
R
CONTROL
TRANSFORMER
Y
W/BK
W/BK
GY
FLOAT SWITCH
(BU)
(R)
(BK)
O
W/BU
INLET
WATER
VALVE
CONTROL SWITCH
DRAIN
VALVE
"F-A"
CONTROL BOARD
BR
W
BR
R
LBU
UPPER
LOWER
115VAC
24VAC
W/O
W/O
LBU
LBU
LBU
W/R
W/R
W/R
W/R
BR
BK
R
W
W
BR
FD BIN CONTROL 1
LBU
OPEN:ICE
CLOSED:DRAIN
BU
R
BK
W/O
W/O
COMPRESSOR
CONTROL RELAY
1
3
5
7
2
4
6
8
2
3
POWER
SWITCH
GY
START CAP.
108-130MFD
RUN CAP.
25MFD
START
RELAY
1
2
5
COMP.
R
C
S
GY
R
R
R
O
BK
BK
BK
BK
BK
HI-PRESS.
SWITCH
CRANKCASE
HEATER
(REMOTE ONLY)
FAN MOTOR
(AIR ONLY)
(BK)
CAP.
5MFD
Y
W
R
W/R
W/O
W/O
(BK)
(BK)
W
W
BR
W
W
BR
BK
BR
BR
BR
(P)
(P)
(T1)
GY
GEAR MOTOR
(BR)
(BR)
FAN MOTOR
(REMOTE ONLY)
(BK)
CAP.
BK
W
FIELD
WIRING
FIELD
WIRING
(W)
(W)
BR
BR
1
2
3
4
5
6
K8
5VDC
K7
5VDC
115VAC
K1
K2
W
BK
(BR)
(BR)
LBU
W/R
BR
BK
R
R
O
O
INTERNAL
PROTECTOR
INTERNAL
PROTECTOR
EVAPORATOR
HEATER
(CUBELET (-C) ONLY)
(BK)
(BK)
W
BIN CONTROL 2
(mechanical)
GY
L2
BR
5
6
BR
BK
208-230/60/1 (3 WIRE WITH NEUTRAL)
O
W W
BK
BK
W/BU
BR
BK
BR
R
BK
W
BK
BK
W
W
GY
W/O
W/O
3
2
1
K6
1 2 3 4 5 6 7 8 9
10
115VAC 24VAC
1
2
3
12345678123456789
S1 DIP SWITCH SETTING 1 2 3 4 5 6 7 8 9 10
FD-1001M_H(-C) ON OFF OFF OFF OFF OFF ON ON OFF OFF
F-1001M_H(-C)
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
BK
BK