Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
79
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 240 V 4.2 RLA 34 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR REMOTE 115 V 3A MAX
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1449 (4.8) 1401 (3.6)
WATER gal./24HR (gal./100 lbs.) 86 (12) 112 (12)
BIN CONTROL SYSTEM (PRIMARY) Photoelectric Sensor (BC1 (Infrared Sensor))
BIN CONTROL SYSTEM (SECONDARY) Proximity Switch (BC2 (Mechanical))
CONDENSER Air-cooled Remote Condenser unit URC-5F Recommended
REFRIGERANT CHARGE R-404A, 4 lb. 1 oz. (1850g)
(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21)
*930
*(423) 895
(406)
860
(390)
80 (26) 825 (375) 790
(360)
760
(345)
90 (32) 730
(332)
*720
*(326)
670
(306)
lbs./day (kg/day) 100 (38) 645
(294)
620
(282) *580 *(263)
APPROXIMATE ELECTRIC 70 (21)
*1401
-- 1408 -- 1415 --
CONSUMPTION 80 (26) 1422 -- 1428 -- 1435 --
90 (32) 1442 --
*1449
-- 1444 --
watts 100 (38) 1440 -- 1435 --
*1430
--
APPROXIMATE WATER 70 (21)
*112 *(423)
108
(406)
103
(390)
CONSUMPTION PER 24 HR. 80 (26) 99
(375)
95
(360)
91
(345)
90 (32) 88
(332) *86 *(326)
81
(306)
gal./day (l/day)
100 (38) 78
(294)
75
(282) *70 *(263)
EVAPORATOR OUTLET TEMP. 70 (21) *5 *(-15) 5 (-15) 5 (-15)
°F (°C) 80 (26) 5 (-15) 9
(-13)
9
(-13)
90 (32) 9
(-13)
*9
*(-13)
12
(-11)
100 (38) 12
(-11)
12
(-11) *12 *(-11)
HEAD PRESSURE 70 (21) *205
*(14.4)
205
(14.4)
205
(14.4)
PSIG (kg/cm²G) 80 (26) 234 (16.5) 234 (16.5) 234 (16.5)
90 (32) 264
(18.6) *264 *(18.6)
264
(18.6)
100 (38) 301 (21.1) 301 (21.1) 301 *(21.1)
SUCTION PRESSURE 70 (21) *33
*(2.3)
33 (2.3) 33 (2.3)
PSIG ( kg/cm²G ) 80 (26) 35 (2.4) 35 (2.4) 35 (2.4)
90 (32) 36
(2.6) *36 *(2.6)
36
(2.6)
100 (38) 39
(2.7)
39
(2.7) *39 *(2.7)
CONDENSERVOLUME 74.5cuin
HEATOFREJECTIONFROMCONDENSER 8900BTU/h(AT90°F/WT70°F)
HEATOFREJECTIONFROMCOMPRESSOR 1400BTU/h(AT90°F/WT70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
ENG F-013.0.1196
14. FD-1001MRH-C