Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
76
11. FD-650MWH-C
Specification Sheet
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 115V 5.5 RLA 50.0 LRA
GEAR MOTOR 120 V 2.3 FLA 1/4 HP
OTHER 115V 0.03A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
ELECTRIC & WATER CONSUMPTION 90/70 (32/21) 21/10 (70/50)
ELECTRIC: W (kWH/100 lbs.) 949 (3.81) 816 (3.2)
POTABLE WATER: gal./24HR (gal./100 l
b
64 (12.0) 74 (12.0)
WATER COOLED CONDENSER 665 (125) 314 (51)
gal./24HR (gal./100lbs)
BIN CONTROL SYSTEM Photoelectric Sensor (BC1 (Infrared Sensor))
REFRIGERANT CHARGE R-404A, 15 oz. (425g)
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) *615 279 601 273 585 265
80 (27) 569 258 554 251 539 245
90 (32) 525 238 *532 241 497 226
lbs./day ( kg/day) 100 (38) 484 220 471 214 *431 196
APPROXIMATE ELECTRIC 70 (21) *816 -- 835 -- 854 --
CONSUMPTION 80 (27) 873 -- 892 -- 911 --
90 (32) 930 -- *949 -- 920 --
Watts 100 (38) 891 -- 861 -- *832 --
APPROXIMATE WATER 70 (21) *390 1476 638 2414 1261 4773
CONSUMPTION PER 24 HR. 80 (27) 410 1551 680 2574 1356 5134
(TOTAL) 90 (32) 433 1640 *703 2660 1461 5528
gal. / day (l/day) 100 (38) 460 1740 778 2946 *1667 6308
EVAPORATOR OUTLET TEMP. 70 (21) *8 -13 9 -13 10 -12
°F (°C) 80 (27) 11 -12 8 -13 9 -13
90 (32) 9 -13 *10 -12 8 -13
100 (38) 9 -13 9 -13 *11 -12
HEAD PRESSURE 70 (21) *272 19 275 19 284 20
PSIG (kg/cm
2
G)
80 (27) 272 19 275 19 284 20
90 (32) 272 19 *275 19 284 20
100 (38) 272 19 275 19 *284 20
SUCTION PRESSURE 70 (21) *41 3 43 3 45 3
PSIG (kg/cm
2
G)
80 (27) 41 3 43 3 45 3
90 (32) 41 3 *43 3 45 3
100 (38) 41 3 43 3 *45 3
264 gal/h (AT 90°F/WT 70°F)
Less than 7 PSIG
74.5 cu in
4500 BTU/h (AT 90°F/WT 70°F)
800 BTU/h (AT 90°F/WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
CONDENSER VOLUME
HEAT OF REJECTION FROM CONDENSER
HEAT OF REJECTION FROM COMPRESSOR
WATER FLOW FOR CONDENSER
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
ENG F-013.0.1196