Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
75
10. FD-650MAH-C
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
COMPRESSOR
115V
7.9 RLA 54.5 LRA
GEAR MOTOR
120 V
2.3 FLA 1/4 HP
FAN MOTOR
115 V
1.0 FLA 1/15 HP
OTHER
115V
0.03A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
SHAPE OF ICE Cubelet
ELECTRIC & WATER CONSUMPTION
90/70°F
ELECTRIC W (kWH/100 lbs.)
1036 (5.35) 274 (3.64)
WATER gal./24HR (gal./100 lbs.)
57 (12.0) 295 (12.0)
BIN CONTROL SYSTEM Photoelectric Sensor (BC1 (Infrared Sensor))
REFRIGERANT CHARGE R-404A, 12.4 oz. (350g)
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 (21) *650 *(295) 627 (284) 593 (269)
80 (26) 576 (261) 523 (237) 490 (222)
90 (32) 490 (222) *474 *(215) 439 (199)
lbs./day (kg/day) 100 (38) 423 (192) 418 (189) *380 *(172)
APPROXIMATE ELECTRIC 70 (21) *971 -- 980 -- 990 --
CONSUMPTION 80 (26) 999 -- 1008 -- 1017 --
90 (32) 1027 -- *1036 -- 1047 --
watts 100 (38) 1057 -- 1068 -- *1078 --
APPROXIMATE WATER 70 (21) *78 *(295) 75 (284) 71 (269)
CONSUMPTION PER 24 HR. 80 (26) 69 (261) 63 (237) 59 (222)
90 (32) 59 (222) *57 *(215) 53 (199)
gal./day (l/day)
100 (38) 51 (192) 50 (189) *46 *(172)
EVAPORATOR OUTLET TEMP. 70 (21) *19 *(-7) 19 (-7) 19 (-7)
°F (°C) 80 (26) 19 (-7) 23 (-5) 23 (-5)
90 (32) 23 (-5) *23 *(-5) 25 (-4)
100 (38) 25 (-4) 25 (-4) *25 *(-4)
HEAD PRESSURE 70 (21) *250 *(17.6) 263 (18.5) 273 (19.2)
PSIG (kg/cm²G) 80 (26) 282 (19.8) 291 (20.4) 300 (21.1)
90 (32) 310 (21.8) *319 *(22.4) 327 (23)
100 (38) 337 (23.7) 348 (24.5) *358 *(25.2)
SUCTION PRESSURE 70 (21) *41 *(2.9) 41 (2.9) 41 (2.9)
PSIG ( kg/cm²G ) 80 (26) 43 (3) 43 (3) 43 (3)
90 (32) 45 (3.2) *45 *(3.2) 46 (3.2)
100 (38) 47 (3.3) 47 (3.3) *47 *(3.3)
TOTAL HEAT OF REJECTION 6800 BTU/h (AT 90°F /WT 70°F)
90 (32)
70/50°F
50 (10) 70 (21)
Water Temp. °F (°C)
ENG F-013.0.1196