Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
66
5a. F-1501MWH
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 208-230 V 9.3 RLA 56 LRA
GEAR MOTOR 120 V 5.6 FLA 400W
CABINET FAN MOTOR 115 V 0.51FLA 8W
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1667 (3.40)
1754 (2.88)
POTABLE WATER 146 (12.0)
175 (12.0)
WAER COOLED CONDENSER 831 (65)
481 (33)
gal./24HR (gal./100 lbs.)
BIN CONTROL SYSTEM (PRIMARY) Photoelectric Sensor (BC1 (Infrared Sensor))
BIN CONTROL SYSTEM (SECONDARY) Proximity Switch (BC2 (Mechanical))
REFRIGERANT CHARGE R-404A, 1 lb. 4 oz. (575g)
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR.
70 (21)
*1460 662 1446 656 1409 639
80 (26)
1374 623 1340 608 1306 592
90 (32)
1273 578 *1265 574 1210 549
lbs./day ( kg/day)
100 (38)
1180 535 1150 522 *1095 497
APPROXIMATE ELECTRIC
70 (21)
*1754 -- 1742 -- 1729 --
CONSUMPTION
80 (26)
1717 -- 1704 -- 1692 --
90 (32)
1679 -- *1667 -- 1668 --
watts
100 (38)
1668 -- 1669 -- *1669 --
APPROXIMATE WATER
70 (21)
*658 2492 996 3769 1663 6295
CONSUMPTION PER 24 HR.
80 (26)
648 2453 983 3721 1651 6248
TOTAL
90 (32)
636 2407 *974 3687 1639 6205
gal. / day (l/day)
100 (38)
625 2364 960 3635 *1625 6152
EVAPORATOR OUTLET TEMP.
70 (21)
*5 (-15) 5 (-15) 5 (-15)
°F (°C)
80 (26)
6 (-15) 6 (-15) 6 (-15)
90 (32)
6 (-15) *6 (-15) 6 (-15)
100 (38)
6 (-15) 6 (-15) *6 (-15)
HEAD PRESSURE
70 (21)
*270 19.0 271 19.0 271 19.1
PSIG (kg/cm2G)
80 (26)
272 19.1 273 19.2 273 19.2
90 (32)
274 19.3 *275 19.3 275 19.3
100 (38)
276 19.4 276 19.4 *277 19.4
SUCTION PRESSURE
70 (21)
*38 2.6 38 2.7 38 2.7
PSIG (kg/cm2G)
80 (26)
38 2.7 38 2.7 38 2.7
90 (32)
39 2.7 39* 2.7 39 2.7
100 (38)
39 2.7 39 2.8 *39 2.8
WATER FLOW FOR CONDENSER 34 gal/h (AT 90°F/WT 70°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER 10100 BTU/h (AT 90°F/WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1800 BTU/h (AT 90°F/WT 70°F)
Water Temp. °F (°C)
50 (10) 70 (21) 90 (32)
ENG.F-013.0.1196