Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
60
2a. F-1001MWH
Specification Shee
t
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 240 V 4.2 RLA 34 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1248 (4.24) 1245 (3.1)
POTABLE WATER 91 (12) 107 (12)
WATER-COOLED CONDENSER 480 (66) 303 (34)
gal./24HR (gal./100 lbs.)
BIN CONTROL SYSTEM Proximity Switch (BC (Mechanical))
REFRIGERANT CHARGE R-404A, 15oz. (425g)
Performance Data Shee
t
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 890 404 855 389 840 380
80 (26) 820 372 805 364 785 356
90 (32) 770 349 755 342 735 334
lbs./DAY ( kg/day) 100 (38) 720 327 705 320 655 297
APPROXIMATE ELECTRIC 70 (21) 1155 -- 1160 -- 1185 --
CONSUMPTION 80 (26) 1155 -- 1160 -- 1185 --
90 (32) 1155 -- 1160 -- 1185 --
watts 100 (38) 1155 -- 1160 -- 1185 --
APPROXIMATE WATER 70 (21) 410 1.86
526 2.39 811 3.69
CONSUMPTION PER 24 HR. 80 (26) 427 1.94 548 2.49 853 3.88
90 (32) 443 2.01 571 2.59 898 4.08
gal. / day (l/day) 100 (38) 461 2.09 599 2.72 989 4.49
EVAPORATOR OUTLET TEMP. 70 (21) 23 -5 23 -5 25 -4
°F (°C) 80 (26) 23 -5 23 -5 25 -4
90 (32) 23 -5 23 -5 25 -4
100 (38) 23 -5 23 -5 25 -4
HEAD PRESSURE 70 (21) 263 18.5 266 18.7 269 18.9
PSIG (kg/sq.cmG) 80 (26) 263 18.5 266 18.7 269 18.9
90 (32) 263 18.5 266 18.7 269 18.9
100 (38) 263 18.5 266 18.7 269 18.9
SUCTION PRESSURE 70 (21) 33 2.3 34 2.4 35 2.5
PSIG (kg/sq.cmG) 80 (26) 33 2.3 34 2.4 35 2.5
90 (32) 33 2.3 34 2.4 35 2.5
100 (38) 33 2.3 34 2.4 35 2.5
WATER FLOW FOR CONDENSER 38 gal/h (AT 100°F /WT 90°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER 7110 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1340 BTU/h (AT 90°F /WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
ENG.F-013.0.1196