Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
58
VII. Technical Information
A. Specication and Performance Data
1a. F-1001MAH
Specification Shee
t
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
COMPRESSOR 240 V 4.2 RLA 34 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR 115 V 0.85FLA 1/15 HP
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1755 (5.7) 1530 (3.8)
WATER gal./24HR (gal./100 lbs.) 89 (12) 116 (12)
BIN CONTROL SYSTEM Proximity Switch (BC (Mechanical))
REFRIGERANT CHARGE R-404A, 1 lb. 12 oz. (800g)
Performance Data Shee
t
APPROXIMATE ICE Ambient
PRODUCTION PER 24 HR. Temp. °F (°C)
70 (21) 970 440
930 422 890 404
80 (26) 855 388 820 372 785 357
90 (32) 755 342 740 336 695 314
lbs./day ( kg/day
)
100 (38) 665 301 635 289 595 207
APPROXIMATE ELECTRIC 70 (21) 1160 -- 1165 -- 1170 --
CONSUMPTION 80 (26) 1175 -- 1185 -- 1190 --
90 (32) 1195 -- 1200 -- 1205 --
watts 100 (38) 1210 -- 1215 -- 1220 --
APPROXIMATE WATER 70 (21) 116 440
112 422.00 107 404.00
CONSUMPTION PER 24 HR. 80 (26) 103 388 98 372.00 94 357.00
90 (32) 90 342 89 336.00 83 314.00
gal. / day (l/day
)
100 (38) 80 301 76 289.00 71 270.00
EVAPORATOR OUTLET TEMP. 70 (21) 19 -7 19 -7 19 -7
°F (°C) 80 (26) 19 -7 23 -5 23 *5
90 (32) 23 -5 23 -5 25 -4
100 (38) 25 -4 25 -4 25 -4
HEAD PRESSURE 70 (21) 213 15.0 213 15.0 213 15.0
PSIG (kg/sq.cmG) 80 (26) 244 17.1 244 17.1 244 17.1
90 (32) 274 1933.0 274 19.3 274 19.3
100 (38) 315 22.1 315 22.1 315 22.1
SUCTION PRESSURE 70 (21) 32 2.3 32 2.3 32 2.3
PSIG (kg/sq.cmG) 80 (26) 35 2.5 35 2.5 35 2.5
90 (32) 38 2.6 38 2.6 38 2.6
100 (38) 41 2.9 41 2.9 41 2.9
Total HEAT OF REJECTION 9100 BTU/h (AT 90°F /WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
ENG.F-013.0.1196