Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
43
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set for infrared sensor bin control operation. No adjustment is
required. When used on a standard ice storage bin, the mechanical bin control may be
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the
factory default position (S1 dip switch 7 in the on position), the gear motor delay after
the upper ๎oat switch closes is 30 sec. When the mechanical bin control is used (S1๎dip
switch 7 in the off position), the gear motor delay after the upper ๎oat switch closes is
5 sec. WARNING! Do not place S1 dip switch 7 in the off position on dispenser unit
applications. This could lead to icemaker movement or ice over๎ow.
Model Bin Control
F-1001M_H(-C) BC (mechanical)
F-1501M_H(-C)
BC1 (infrared sensor) with
BC2 (mechanical backup)
F-2001M_H(-C)
FD-1001M_H(-C)
FD-650M_H-C BC1 (infrared sensor)
S1 Dip Switch
Setting
Bin Control Application Gear Motor Delay
No. 7
OFF BC (mechanical stand-alone) (Standard Ice Storage Bins Only) 5 seconds
ON
BC1 (infrared sensor) Stand-Alone and
BC1 (infrared sensor) with
BC2 (mechanical backup)
30 seconds
6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
Not available when S1 dip switch 7 is on. Factory set for normal operation. No adjustment
is required. The shutdown delay is the time between the mechanical bin control proximity
switch opening and the control board shutting off the icemaker. Note: When used in
conjunction with BC1, shutdown is immediate and CB sounds a 9 beep alarm.
S1 Dip Switch
Setting
Shutdown Delay
No. 8
OFF 0.25 Seconds
ON 6.7 Seconds
7. Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.