Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC (Mechanical Stand-Alone) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification and Performance Data
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-1001MAJ
- 15b. F-1001MAJ-C
- 16a. F-1001MWJ
- 16b. F-1001MWJ-C
- 17a. F-1001MRJ
- 17b. F-1001MRJ-C
- 18. FD-1001MAJ-C
- 19. FD-1001MRJ-C
- B. Wiring Diagrams
- A. Specification and Performance Data
20
6) Startup–CB "POWER OK" LED is on. Turn on the power supply, then move the power
switch to the "ON" position. Make sure the control switch is in the "ICE" position. CB
"POWER OK" LED and
IS (BC1 if applicable) green LED turn on.
Diagnosis CB "POWER OK" LED: Check that CB "POWER OK" LED is on. If not,
check for 115VAC at control transformer brown (BR (BK on F-2001MLH)) wire to neutral
(W). If 115VAC is not present, check the power switch and breaker. If 115VAC is present,
check control transformer continuity. Replace as needed. Next, check for 24VAC at
control transformer red (R) wire to neutral (LBU). If 24VAC is not present, check control
transformer continuity. Replace as needed. If 24VAC is present, check 24VAC 1A fuse.
If fuse is good, check for 24VAC at CB K8 #1 (W/R) to CB K8 #2 (LBU). If 24VAC is
present and "POWER OK" LED is off, replace CB.
Diagnosis BC1 (infrared sensor): If "POWER OK" LED is on and BC1 green LED
is off, check 20VDC at CB K6 #1 (DBU) to CB K6 #3 (BR). If 20VDC is not present,
conrm dip switch 7 is in the "ON" position. If dip switch 7 is in the "ON" position and
20VDC is not present, replace CB. If BC1 yellow LED is on or ashing, move ice away
from lens. If no ice is present, clean the lens with a warm, clean damp cloth. If cleaning
the lens does not work, replace BC1.
Diagnosis BC(2) (mechanical stand-alone or backup): Check that the actuator
paddle is properly positioned. Check continuity across BC(2). If open, replace BC(2).
Next, check VDC at CB K8#3(GY) to CB K8 #4 (GY). When BC(2)is closed 0VDC is
read. Move the actuator paddle to open BC(2). When open, 5VDCis present between
CB K8 #3 (GY) and CB K8#4(GY). If 5VDC is not present when BC(2) is open, replace
CB. Return actuator to its normal position.
7) Fill Cycle – "WTRIN" LED is on. Reservoir is empty and LFS and UFS are open.
FT starts. WV energizes and ll cycle starts. LFS closes. Nothing occurs at this time.
Nothing happens at this time. Reservoir continues to ll until UFS closes. When UFS
closes, FT terminates, WV de-energizes, and CB "WTRIN" LED turns off. FZTand
30-sec. GM delay timer start. If UFS remains open longer than 90 sec. after LFS
opens, FTexceeded and CB sounds a 1-beep alarm. WVremains energized until UFS
closes. Alarm resets automatically when UFS closes. Diagnosis: If reservoir is empty
and "WTRIN" LED is off, conrm LFS status. See "II.E.1. Float Switch Check." IfLFS
is open and "WTRIN" LED is off, replace CB. If "WTRIN" LED is on, check that the
reservoir lls. If not, check water supply line shut-off valve, water lters, and WVscreen.
If "WTRIN" LED is on and WV is off, check CB K2 #8(O) to a neutral (LBU) for 24VAC.
If24VAC is not present, check CB K2 #9(W/R) to a neutral (LBU) for 24VAC. If 24VAC
is present on CB K2 #9(W/R)and not on CB K2 #8 (O), replace CB. If 24VAC is
present on CB K2 #8(O), check continuity through WV solenoid. If open, replace WV.
If WV is energized and rell exceeds FT with no water in the reservoir, check for DV
leaking. Ifreservoir is full and overowing check for open UFS. See "II.E.1. Float Switch
Check." If UFS is closed, check that WV de-energizes. If not, check CB K2 #8 (O) to a
neutral (LBU) for 24VAC. If 24VAC is present, replace CB. IfWV de-energizes and water
continues to ll the reservoir, replace WV.