Instruction Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- A. Electrical and Refrigerant Data
- B. Dimensions/Connections
- 1. Air-Cooled Models (MAH/MAJ(-C))
- 2. Water-Cooled Models (MWH(-C))
- 3. Remote Models (MRH/MRJ(3)(-C)) and Low-Side Models (MLH(-C))
- 4. Remote Condenser Unit URC-5F (use with FD-1001MRJ-C)
- 5. Remote Condenser Unit URC-14F (use with F-1501MRH(-C))
- 6. Remote Condenser Unit URC-22F (use with F-2001MRH(3)(-C))
- II. Installation and Operating Instructions
- A. Location
- B. Checks Before Installation
- C. How to Remove Panels
- D. Dispenser Unit/Ice Storage Bin and Icemaker Setup
- E. Electrical Connection
- F. Water Supply and Drain Connections
- G. Installation of Remote Condenser Unit for Remote Models
- H. Connection to an R-404A Parallel Rack System for Low-Side Models
- I. Final Checklist
- J. Startup
- K. Bin Control Check
- L. Alarm Safeties
- III. Maintenance
- IV. Preparing the Icemaker for Periods of Non-Use
- V. Disposal
15
• Remove the protective plastic lm from the panels. If the appliance is exposed to the
sun or to heat, remove the lm after the appliance cools.
• Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade (if applicable) turns freely.
• Check that the compressor is snug on all mounting pads.
• Flaker models can be installed on an ice storage bin only. Cubelet models can be
installed on either a dispenser unit or an ice storage bin. The ice storage bins listed
below are recommended.
Model Number Bin Width Recommended Hoshizaki Ice Storage Bin
FD-1001M_J-C 22" or Wider BD-300 Series
F-1501M_H(-C)
F-2001M_H(3)(-C)
30" or Wider B-500 Series
For further options, contact your local Hoshizaki distributor.
• NOTICE! Remote models must be connected to an appropriate remote condenser
unit. The remote condenser units listed below are recommended. Connection to a
different remote condenser unit will void the warranty unless Hoshizaki approves
a different remote condenser unit for your specic application. For further
details, contact your local Hoshizaki distributor.
Model Number Recommended Hoshizaki Remote Condenser Unit
FD-1001MRJ-C URC-5F
F-1501MRH(-C) URC-14F
F-2001MRH(3)(-C) URC-22F
• On low-side models, an R-404A parallel rack system is needed. See "II.H. Connection
to an R-404A Parallel Rack System" for refrigeration circuit details.
C. How to Remove Panels
See Fig. 1
• Front Panel: Remove the screw. Lift up and towards you.
• Top Panel: Lift up at front slightly, push rearward and lift off.
• Side Panels: Remove the screw. Slide forward slightly and lift off.
Fig. 1
Model Shown: F-1501MRH-C
Top Panel
Side Panel
Side Panel
Front Panel