Instruction Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- A. Electrical and Refrigerant Data
- B. Dimensions/Connections
- 1. Air-Cooled Models (MAH/MAJ(-C))
- 2. Water-Cooled Models (MWH(-C))
- 3. Remote Models (MRH/MRJ(3)(-C)) and Low-Side Models (MLH(-C))
- 4. Remote Condenser Unit URC-5F (use with FD-1001MRJ-C)
- 5. Remote Condenser Unit URC-14F (use with F-1501MRH(-C))
- 6. Remote Condenser Unit URC-22F (use with F-2001MRH(3)(-C))
- II. Installation and Operating Instructions
- A. Location
- B. Checks Before Installation
- C. How to Remove Panels
- D. Dispenser Unit/Ice Storage Bin and Icemaker Setup
- E. Electrical Connection
- F. Water Supply and Drain Connections
- G. Installation of Remote Condenser Unit for Remote Models
- H. Connection to an R-404A Parallel Rack System for Low-Side Models
- I. Final Checklist
- J. Startup
- K. Bin Control Check
- L. Alarm Safeties
- III. Maintenance
- IV. Preparing the Icemaker for Periods of Non-Use
- V. Disposal
10
2. Water-Cooled Models (MWH(-C))
Units: mm [in.]
F-1501MWH(-C) F-2001MWH(-C)
A 768 [30-1/4] 768 [30-1/4]
B 762 [30] 762 [30]
C 602 [23-3/4] 602 [23-3/4]
D 874 [34-3/8] 874 [34-3/8]
E 821 [32-3/8] 821 [32-3/8]
F 731 [28-3/4] 705 [27-3/4]
G 170 [6-3/4] 170 [6-3/4]
H 25 [1] 25 [1]
I 44 [1-3/4] 44 [1-3/4]
J 87 [3-3/8] 76 [3]
K 371 [14-5/8] 330 [13]
L 139 [5-1/2] 178 [7]
M 127 [5] 51 [2]
RearSide
Model Shown: F-1501MWH
Model Shown: F-1501MWH
Model Shown: F-1501MWH
Bottom
NOTICE
• Allow 6" (15 cm) clearance at rear
and sides for proper air circulation
and ease of maintenance and/or
service should they be required. Allow
24"(61cm) clearance at top to allow
for removal of the auger.
• The dispenser unit/ice storage bin
opening must accommodate the
bottom opening as in the illustration.