Service Guide
26
Comp and ConFM: Check for 115VAC at CM C1 (R or V) to neutral(W).
If115VAC is not present, check CTh status. See "II.D.Thermistor Check." If CTh
ohm reading is in proper range, replace CM. If 115VAC is present, check for
115VAC at CR #4(BK) to neutral (W) and CR#6(R) to neutral (W). If 115VAC is
present at CR #4 (BK) to neutral (W) but not at CR #6(R) to neutral (W), replace
CR. If 115VAC is present at CR #6 (R) and Comp or ConFM are not energized,
check Comp start components, Comp protector (internal on 1-section, external
on 2-section), and Comp motor winding continuity. If ConFM is not energized,
check ConFM fan blades for binding and motor winding continuity.
EvapFM: Conrm EvapFM icon turns on and EvapFM energizes. If not, conrm
doors are closed and DS engaged. Next, check for 115VAC at CMF5 (Y or
W/BU) to neutral (W). If 115VAC is not present, replace CM. If 115VAC is present,
checkfor 115VAC at DSR#4(DBU) to neutral(W). If115VAC is not present,
check for 115VAC at DSR#6(Y or W/BU) to neutral (W). If115VAC is present
on DSR #6 (Y or W/BU) to neutral (W) and not on DSR #4(DBU) to neutral (W),
replace DSR. If 115VAC is present on DSR #4 (DBU) to neutral (W) and EvapFM
is not energized, check EvapFM blades for binding and EvapFM continuity.
(2) 15-min. temperature display delay timer terminates: 12 min. after Comp,
ConFM, and EvapFM energize, "dEF" is replaced by cabinet temperature on
display. If not, replace CM.
Legend: CL–cabinet light; CLS–cabinet light switch; CM–control module;
Comp–compressor; ConFM–condenser fan motor; CR–compressor relay;
CTh–cabinet thermistor; DCD–direct current driver; DH–defrost heater; DrH–drain
heater; DSR–door switch relay; DT–defrost thermostat; DTh–defrost thermistor;
EvapFM–evaporator fan motors; HPS–high-pressure switch; MH–mullion heater;
PH–perimeter heater; TXV–thermostatic expansion valve