(3) Comp and ConFM Diagnosis: Conrm Comp and ConFM de-energize.
If not, check for 115VAC at CR #6(R) to neutral (W). If 115VAC is present,
replace CR.
(4) EvapFM Diagnosis: Conrm EvapFM de-energizes. If not, check for 115VAC at
DSR 4 (DBU) to neutral (W). If 115VAC is present, replace DSR.
2a) Time-Initiated Defrost-Termination: DTh warms to 59°F (15°C). If not, conrm
DTh status. See "II.D. Thermistor Check." IfDTh is in proper range, DHde-energizes
and 3 delay timers start. If DTh has not warmed to 59°F (15°C), check DT and DH
continuity. Next, check DH amp draw.
(1) 3-min. Comp delay timer terminates: 3 min. after DH de-energizes, conrm
defrost icon turns off, Comp icon turns on, and Comp and ConFM energize.
If not, conrm cabinet temperature is warm enough for Comp and ConFM
operation. Next, check for 115VAC at CM C1 (R or V) to neutral(W). If 115VAC
is not present, check CTh status. See "II.D.Thermistor Check." If CTh ohm
reading is in proper range, replace CM. If 115VAC is present, check for 115VAC
at CR#4(BK) to neutral (W) and CR#6(R) to neutral (W). If 115VAC is present
at CR #4 (BK) to neutral (W) but not at CR #6(R) to neutral (W), replace CR.
If115VAC is present at CR #6 (R) and Comp or ConFM are not energized, check
Comp start components, Comp protector (internal on 1-section, external on
2-section), and Comp motor winding continuity. If ConFM is not energized, check
ConFM fan blades for binding and motor winding continuity.
(2) 7-min. EvapFM delay timer terminates: (note that the 7-min. EvapFM delay
time is a maximum; if the defrost thermistor cools to 25°F (-3.9°C) before the
7-min. EvapFM delay timer terminates, EvapFM icon turns on and EvapFM
energizes): 4min. after Comp and ConFM energize, conrm EvapFM icon turns
on and EvapFM energizes. If not, conrm doors are closed and DS engaged.
Next, check for 115VAC at CMF5 (Y or W/BU) to neutral (W). If 115VAC is not
present, replace CM. If 115VAC is present, checkfor 115VAC at DSR#4(DBU) to
neutral(W). If115VAC is not present, check for 115VAC at DSR#6(Y or W/BU)
to neutral (W). If115VAC is present on DSR #6 (Y or W/BU) to neutral (W) and
not on DSR #4(DBU) to neutral (W), replace DSR. If 115VAC is present on DSR
#4 (DBU) to neutral (W) and EvapFM is not energized, check EvapFM blades for
binding and EvapFM continuity.
(3) 18-min. temperature display delay timer terminates: 11 min. after EvapFM
energizes, "dEF" is replaced by cabinet temperature on display. If not, replace
CM.
2b) Manually-Initiated Defrost-Termination: DTh warmes to 59°F (15°C). Ifnot,
conrm DTh status. See "II.D. Thermistor Check." If DTh is in proper range,
DHde-energizes and 2 delay timers start. If DTh has not warmed to 59°F (15°C),
check DT and DH continuity. Next, check DH amp draw.
(1) 3-min. Comp/ConFM and EvapFM delay timers terminate: 3 min. after DH
de-energizes, conrm defrost icon turns off, Comp and EvapFM icons turn on,
and Comp, ConFM, and EvapFM energize. If not, conrm cabinet temperature is
warm enough for Comp and ConFM operation.