Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC(2) (Mech. Stand-Alone or Backup (only)) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-450MAJ
- 15b. F-450MAJ-C
- 16a. F-801MAJ
- 16b. F-801MAJ-C
- 17a. F-801MWJ
- 17b. F-801MWJ-C
- 18a. F-1001MAJ
- 18b. F-1001MAJ-C
- 19a. F-1001MWJ
- 19b. F-1001MWJ-C
- 20a. F-1001MRJ
- 20b. F-1001MRJ-C
- 21a. F-1001MLJ
- 21b. F-1002MLJ
- 22a. F-1002MAJ
- 22b. F-1002MAJ-C
- 23a. F-1002MWJ
- 23b. F-1002MWJ-C
- 24a. F-1002MRJ
- 24b. F-1002MRJ-C
- 25a. F-1501MAJ
- 25b. F-1501MAJ-C
- 26a. F-1501MWJ
- 26b. F-1501MWJ-C
- 27a. F-1501MRJ
- 27b. F-1501MRJ-C
- 28a. F-2001MLJ
- 28b. F-2001MWJ
- 28c. F-2001MRJ
- 28d. F-2001MRJ-C
- 28e. F-2001MRJ3
- 29. FD-1001MAJ-C
- 30. FD-1001MRJ-C
- 31. FD-1002MAJ-C
- 32. FD-1002MRJ-C
- B. Wiring Diagrams
- 1. F-1001MAH(-C), F-1001MWH(-C), F-1001MRH(-C), FD-1001M_H-C
- 2. F-1501M_H(-C)
- 3. F-2001MWH(-C), F-2001MRH(-C)(3),F-2001MWJ, F-2001MRJ(-C)(3)
- 4. F-2001MLH, F-1001MLJ, F-1002MLJ, F-2001MLJ
- 5. FD-650M_H-C
- 6. F-450MAJ(-C)
- 7. F-801M_J(-C)
- 8. F-1001MAJ(-C), F-1001MWJ(-C), F-1001MRJ(-C)
- 9. F-1002MAJ(-C), F-1002MWJ(-C), F-1002MRJ(-C), FD-1002M_J-C
- 10. F-1501M_J(-C)
- 11. FD-1001M_J-C
- A. Specification & Performance Data Sheets
77
11. FD-650MWH-C
Specification Shee
t
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 115V 5.5 RLA 50.0 LRA
GEAR MOTOR 120 V 2.3 FLA 1/4 HP
OTHER 115V 0.03A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
ELECTRIC & WATER CONSUMPTION 90/70 (32/21) 21/10 (70/50)
ELECTRIC: W (kWH/100 lbs.) 949 (3.81) 816 (3.2)
POTABLE WATER: gal./24HR (gal./100 lbs.) 64 (12.0) 74 (12.0)
WATER COOLED CONDENSER 665 (125) 314 (51)
gal./24HR (gal./100lbs)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 88%, Ice (90/70°F), Conductivity 200 μs/cm)
BIN CONTROL SYSTEM Photoelectric Sensor (BC1 (Infrared Sensor))
REFRIGERANT CHARGE R-404A, 15 oz. (425g)
Performance Data Shee
t
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 615 279 601 273 585 265
80 (27) 569 258 554 251 539 245
90 (32) 525 238 532 241 497 226
lbs./day ( kg/day) 100 (38) 484 220 471 214 431 196
APPROXIMATE ELECTRIC 70 (21) 816 -- 835 -- 854 --
CONSUMPTION 80 (27) 873 -- 892 -- 911 --
90 (32) 930 -- 949 -- 920 --
Watts 100 (38) 891 -- 861 -- 832 --
APPROXIMATE WATER 70 (21) 390 1476 638 2414 1261 4773
CONSUMPTION PER 24 HR. 80 (27) 410 1551 680 2574 1356 5134
(TOTAL) 90 (32) 433 1640 703 2660 1461 5528
gal. / day (l/day) 100 (38) 460 1740 778 2946 1667 6308
EVAPORATOR OUTLET TEMP. 70 (21) 8 -13 9 -13 10 -12
°F (°C) 80 (27) 11 -12 8 -13 9 -13
90 (32) 9 -13 10 -12 8 -13
100 (38) 9 -13 9 -13 11 -12
HEAD PRESSURE 70 (21) 272 19 275 19 284 20
PSIG (kg/cm
2
G)
80 (27) 272 19 275 19 284 20
90 (32) 272 19 275 19 284 20
100 (38) 272 19 275 19 284 20
SUCTION PRESSURE 70 (21) 41 3 43 3 45 3
PSIG (kg/cm
2
G)
80 (27) 41 3 43 3 45 3
90 (32) 41 3 43 3 45 3
100 (38) 41 3 43 3 45 3
264 gal/h (AT 90°F/WT 70°F)
Less than 7 PSIG
74.5 cu in
4500 BTU/h (AT 90°F/WT 70°F)
800 BTU/h (AT 90°F/WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
PRESSURE DROP OF COOLING WATER LINE
CONDENSER VOLUME
HEAT OF REJECTION FROM CONDENSER
HEAT OF REJECTION FROM COMPRESSOR
WATER FLOW FOR CONDENSER
ENG F-013.0.1196