Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC(2) (Mech. Stand-Alone or Backup (only)) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-450MAJ
- 15b. F-450MAJ-C
- 16a. F-801MAJ
- 16b. F-801MAJ-C
- 17a. F-801MWJ
- 17b. F-801MWJ-C
- 18a. F-1001MAJ
- 18b. F-1001MAJ-C
- 19a. F-1001MWJ
- 19b. F-1001MWJ-C
- 20a. F-1001MRJ
- 20b. F-1001MRJ-C
- 21a. F-1001MLJ
- 21b. F-1002MLJ
- 22a. F-1002MAJ
- 22b. F-1002MAJ-C
- 23a. F-1002MWJ
- 23b. F-1002MWJ-C
- 24a. F-1002MRJ
- 24b. F-1002MRJ-C
- 25a. F-1501MAJ
- 25b. F-1501MAJ-C
- 26a. F-1501MWJ
- 26b. F-1501MWJ-C
- 27a. F-1501MRJ
- 27b. F-1501MRJ-C
- 28a. F-2001MLJ
- 28b. F-2001MWJ
- 28c. F-2001MRJ
- 28d. F-2001MRJ-C
- 28e. F-2001MRJ3
- 29. FD-1001MAJ-C
- 30. FD-1001MRJ-C
- 31. FD-1002MAJ-C
- 32. FD-1002MRJ-C
- B. Wiring Diagrams
- 1. F-1001MAH(-C), F-1001MWH(-C), F-1001MRH(-C), FD-1001M_H-C
- 2. F-1501M_H(-C)
- 3. F-2001MWH(-C), F-2001MRH(-C)(3),F-2001MWJ, F-2001MRJ(-C)(3)
- 4. F-2001MLH, F-1001MLJ, F-1002MLJ, F-2001MLJ
- 5. FD-650M_H-C
- 6. F-450MAJ(-C)
- 7. F-801M_J(-C)
- 8. F-1001MAJ(-C), F-1001MWJ(-C), F-1001MRJ(-C)
- 9. F-1002MAJ(-C), F-1002MWJ(-C), F-1002MRJ(-C), FD-1002M_J-C
- 10. F-1501M_J(-C)
- 11. FD-1001M_J-C
- A. Specification & Performance Data Sheets
76
10. FD-650MAH-C
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
COMPRESSOR
115V
7.9 RLA 54.5 LRA
GEAR MOTOR
120 V
2.3 FLA 1/4 HP
FAN MOTOR
115 V
1.0 FLA 1/15 HP
OTHER
115V
0.03A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.)
1036 (5.35) 274 (3.64)
WATER gal./24HR (gal./100 lbs.)
57 (12.0) 295 (12.0)
SHAPE OF ICE Cubelet
ICE QUALITY
Approx. 86%, Ice (90/70°F, Conductivity 200 μs/cm)
BIN CONTROL SYSTEM Photoelectric Sensor (BC1 (Infrared Sensor))
REFRIGERANT CHARGE R-404A, 12.4 oz. (350g)
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 (21) 650 (295) 627 (284) 593 (269)
80 (26) 576 (261) 523 (237) 490 (222)
90 (32) 490 (222) 474 (215) 439 (199)
lbs./day (kg/day) 100 (38) 423 (192) 418 (189) 380 (172)
APPROXIMATE ELECTRIC 70 (21) 971 -- 980 -- 990 --
CONSUMPTION 80 (26) 999 -- 1008 -- 1017 --
90 (32) 1027 -- 1036 -- 1047 --
watts 100 (38) 1057 -- 1068 -- 1078 --
APPROXIMATE WATER 70 (21) 78 (295) 75 (284) 71 (269)
CONSUMPTION PER 24 HR. 80 (26) 69 (261) 63 (237) 59 (222)
90 (32) 59 (222) 57 (215) 53 (199)
gal./day (l/day)
100 (38) 51 (192) 50 (189) 46 (172)
EVAPORATOR OUTLET TEMP. 70 (21) 19 (-7) 19 (-7) 19 (-7)
°F (°C) 80 (26) 19 (-7) 23 (-5) 23 (-5)
90 (32) 23 (-5) 23 (-5) 25 (-4)
100 (38) 25 (-4) 25 (-4) 25 (-4)
HEAD PRESSURE 70 (21) 250 (17.6) 263 (18.5) 273 (19.2)
PSIG (kg/cm²G) 80 (26) 282 (19.8) 291 (20.4) 300 (21.1)
90 (32) 310 (21.8) 319 (22.4) 327 (23)
100 (38) 337 (23.7) 348 (24.5) 358 (25.2)
SUCTION PRESSURE 70 (21) 41 (2.9) 41 (2.9) 41 (2.9)
PSIG ( kg/cm²G ) 80 (26) 43 (3) 43 (3) 43 (3)
90 (32) 45 (3.2) 45 (3.2) 46 (3.2)
100 (38) 47 (3.3) 47 (3.3) 47 (3.3)
TOTAL HEAT OF REJECTION 6800 BTU/h (AT 90°F /WT 70°F)
90 (32)50 (10) 70 (21)
Water Temp. °F (°C)
ENG F-013.0.1196