Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board
- B. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. BC1 (Infrared Sensor) Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. BC(2) (Mech. Stand-Alone or Backup (only)) Shutdown Delay (S1 dip switch 8)
- 7. Factory Use (S1 Dip Switch 9 & 10)
- C. Power Switch and Control Switch
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Disposal
- VII. Technical Information
- A. Specification & Performance Data Sheets
- 1a. F-1001MAH
- 1b. F-1001MAH-C
- 2a. F-1001MWH
- 2b. F-1001MWH-C
- 3a. F-1001MRH
- 3b. F-1001MRH-C
- 4a. F-1501MAH
- 4b. F-1501MAH-C
- 5a. F-1501MWH
- 5b. F-1501MWH-C
- 6a. F-1501MRH
- 6b. F-1501MRH-C
- 7. F-2001MWH
- 8a. F-2001MRH
- 8b. F-2001MRH-C
- 8c. F-2001MRH3
- 9. F-2001MLH
- 10. FD-650MAH-C
- 11. FD-650MWH-C
- 12. FD-650MRH-C
- 13. FD-1001MAH-C
- 14. FD-1001MRH-C
- 15a. F-450MAJ
- 15b. F-450MAJ-C
- 16a. F-801MAJ
- 16b. F-801MAJ-C
- 17a. F-801MWJ
- 17b. F-801MWJ-C
- 18a. F-1001MAJ
- 18b. F-1001MAJ-C
- 19a. F-1001MWJ
- 19b. F-1001MWJ-C
- 20a. F-1001MRJ
- 20b. F-1001MRJ-C
- 21a. F-1001MLJ
- 21b. F-1002MLJ
- 22a. F-1002MAJ
- 22b. F-1002MAJ-C
- 23a. F-1002MWJ
- 23b. F-1002MWJ-C
- 24a. F-1002MRJ
- 24b. F-1002MRJ-C
- 25a. F-1501MAJ
- 25b. F-1501MAJ-C
- 26a. F-1501MWJ
- 26b. F-1501MWJ-C
- 27a. F-1501MRJ
- 27b. F-1501MRJ-C
- 28a. F-2001MLJ
- 28b. F-2001MWJ
- 28c. F-2001MRJ
- 28d. F-2001MRJ-C
- 28e. F-2001MRJ3
- 29. FD-1001MAJ-C
- 30. FD-1001MRJ-C
- 31. FD-1002MAJ-C
- 32. FD-1002MRJ-C
- B. Wiring Diagrams
- 1. F-1001MAH(-C), F-1001MWH(-C), F-1001MRH(-C), FD-1001M_H-C
- 2. F-1501M_H(-C)
- 3. F-2001MWH(-C), F-2001MRH(-C)(3),F-2001MWJ, F-2001MRJ(-C)(3)
- 4. F-2001MLH, F-1001MLJ, F-1002MLJ, F-2001MLJ
- 5. FD-650M_H-C
- 6. F-450MAJ(-C)
- 7. F-801M_J(-C)
- 8. F-1001MAJ(-C), F-1001MWJ(-C), F-1001MRJ(-C)
- 9. F-1002MAJ(-C), F-1002MWJ(-C), F-1002MRJ(-C), FD-1002M_J-C
- 10. F-1501M_J(-C)
- 11. FD-1001M_J-C
- A. Specification & Performance Data Sheets
64
3b. F-1001MRH-C
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral)
4.2 RLA 34 LRA 5.9 RLA 46 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR REMOTE 120 V 3A MAX
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 15 A
MAX. HACR BREAKER (USA ONLY) 15 A
MAX. CIRC. BREAKER (CANADA ONLY) 15 A
MINIMUM CIRCUIT AMPACITY 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1605 (5.08) 1610 (4.6)
WATER gal./24HR (gal./100 lbs.) 83 (12) 101(12)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
BIN CONTROL SYSTEM Proximity Switch (BC (Mechanical))
CONDENSER Air-cooled Remote Condenser unit URC-5F Recommended
REFRIGERANT CHARGE R-404A, 4 lb. 1 oz. (1850g)
(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )
Performance Data Sheet
APPROXIMATE Ambient
ICE PRODUCTION Temp. °F (°C)
PER 24 HR. 70 (21) 840 381 810 368 790 358
80 (26) 765 347 745 337 720 327
90 (32) 700 317 695 315 660 299
lbs./DAY ( kg/day) 100 (38) 640 290 620 282 575 261
APPROXIMATE ELECTRIC 70 (21) 1300 -- 1300 -- 1305 --
CONSUMPTION 80 (26) 1305 -- 1305 -- 1305 --
90 (32) 1310 -- 1310 -- 1320 --
watts 100 (38) 1325 -- 1335 -- 1340 --
APPROXIMATE WATER 70 (21) 101 381 98 368 95 358
CONSUMPTION PER 24 HR. 80 (26) 92 347 89 337 87 327
90 (32) 84 317 83 315 79 299
gal. / day (l/day) 100 (38) 77 290 75 282 69 261
EVAPORATOR OUTLET TEMP. 70 (21) 23 -5 24 -4 25 -4
°F (°C) 80 (26) 25 -4 26 -3 26 -3
90 (32) 26 -3 25 -4 28 -2
100 (38) 28 -2 28 -2 28 -2
HEAD PRESSURE 70 (21) 220 15.5 220 15.5 220 15.5
80 (26) 238 16.7 238 16.7 238 16.7
90 (32) 256 18.0 256 18.0 256 18.0
PSIG (kg/sq.cmG) 100 (38) 295 20.7 295 20.7 295 20.7
SUCTION PRESSURE 70 (21) 34 2.4 34 2.4 34 2.4
PSIG (kg/sq.cmG) 80 (26) 36 2.5 36 2.5 36 2.5
90 (32) 37 2.6 37 2.6 37 2.6
100 (38) 40 2.8 40 2.8 40 2.8
CONDENSER VOLUME 74.5 cu in
HEAT OF REJECTION FROM CONDENSER 7840 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1400 BTU/h (AT 90°F /WT 70°F)
50 (10) 70 (21) 90 (32)
Water Temp. °F (°C)
COMPRESSOR 240 V
Aux. Code C-1
and Earlier
Aux. Code C-2
and Later
ENG.F-013.0.1196