Model Number F-2001MWH(-C) F-2001MRH(-C) F-2001MLH(-C)
AC Supply Voltage 208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
115/60/1
Compressor 240V 10.8RLA 96LRA 240V 10.8RLA 96LRA --- --- ---
Gear Motor 120V 5.6FLA 400W 120V 5.6FLA 400W 120V 5.6FLA 400W
Fan Motor Cabinet: 115V 0.51FLA 8W Cabinet: 115V 0.51FLA 8W Cabinet: 115V 0.51FLA 8W
Remote: 120V 3A MAX
Other 120V 0.03A 120V 0.03A 120V 0.03A
Maximum Fuse Size 30 AMPS 30 AMPS 15 AMPS
Max. HACR Breaker
(USA Only)
30 AMPS 30 AMPS 15 AMPS
Max. Circuit Breaker
(Canada Only)
30 AMPS 30 AMPS 15 AMPS
Minimum Circuit
Ampacity
30 AMPS 30 AMPS 15 AMPS
Design Pressure HI - 460PSI LO - 290PSI HI - 460PSI LO - 290PSI HI - 460PSI LO - 290PSI
Refrigerant 404A 2 LB. 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22F: 14 LB. 9 OZ.
404A
Three Phase
Model Number F-2001MRH3(-C)
AC Supply Voltage 208-230/60/3
Compressor 240V 9.0RLA 75LRA
Gear Motor 120V 5.6FLA 400W
Fan Motor Cabinet: 115V 0.51FLA 8W
Remote: 120V 3A MAX
Other 120V 0.03A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
Design Pressure HI - 460PSI LO - 290PSI
Refrigerant 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-22F: 14 LB. 9 OZ.