Instruction Manual
7
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. FD-1001M_J-C
Single Phase
Model Number FD-1001MAJ-C FD-1001MRJ-C
AC Supply Voltage 115/60/1 115/60/1
Compressor 115V 12RLA 93LRA 115V 11.2RLA 93LRA
Gear Motor 115V 3.0FLA 200W 115V 3.0FLA 200W
Fan Motor 115V 1.0FLA 1/15HP Remote 115V 1.0FLA 1/12HP
Other 120V 0.03A 120V 0.53A
Maximum Fuse Size 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS
Design Pressure HI - 427PSI LO - 230PSI HI - 427PSI LO - 230PSI
Refrigerant 404A 2 LB. 4.1 OZ. 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-5F: 4 LB. 1.2 OZ.
2. F-1501M_H(-C)
Single Phase
Model Number F-1501MAH(-C) F-1501MWH(-C) F-1501MRH(-C)
AC Supply Voltage 208-230/60/1(3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
Compressor 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA
Gear Motor 120V 5.6FLA 400W 120V 5.6FLA 400W 120V 5.6FLA 400W
Fan Motor 115V 1.0FLA 1/15HP Cabinet: 115V 0.51FLA 8W Cabinet: 115V 0.51FLA 8W
Remote: 120V 3A MAX
Other 120V 0.03A 120V 0.03A 120V 0.03A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS
Design Pressure HI - 427PSI LO - 230PSI HI - 427PSI LO - 230PSI HI - 427PSI LO - 230PSI
Refrigerant 404A 2 LB. 5 OZ. 404A 1 LB. 4 OZ. 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 9 LB. 9 OZ.