Instruction Manual

31
CO
2
Tank Replacement
If the arrow on the “Capacity Gauge” is in the red region, it is time to replace the CO
2
tank. Follow these steps below:
1. Fully close the main valve on top of the CO
2
tank.
2. Release gas pressure by touching the green button on the water dispenser and dispensing sparkling water, or by
pulling the gas valve (see fig 6 on page 18).
3. Shut the the CO
2
regulator, turning the knob counter-clockwise until the arrow on the “Gas Pressure Gauge” is
close to zero.
4. Using a wrench, remove the regulator from the empty tank.
5. Screw the CO
2
regulator to the new (full) tank.
6. Open the main valve on top of the tank completely.
7. Open the CO
2
valve (clockwise) on the regulator knob.
8. Reset the gas pressure to the desired level (i.e. the arrow must be in the green region).
Cleaning and Sanitation
WARNING
SANITARY GLOVES ARE TO BE USED DURING CLEANING OPERATIONS. APPLICABLE SAFETY
PRECAUTIONS MUST BE OBSERVED. INSTRUCTION WARNINGS ON THE PRODUCT MUST BE
FOLLOWED.
CLEANING SOLUTIONS CONTAIN ACIDS. THESE COMPOUNDS MAY CAUSE BURNS. IF SWALLOWED, DO
NOT INDUCE VOMITING. CALL PHYSICIAN IMMEDIATELY. IN THE CASE OF EXTERNAL CONTACT, FLUSH
WITH WATER. KEEP OUT OF REACH OF CHILDREN.
The DWM-20A is constructed with high quality stainless steel. Cleaning with a glass cleaner and a soft cotton cloth
will keep the stainless steel of the DWM-20A clean. Using sparkling water to clean external surfaces is also an option.
Surface Finish Care
Do not use cleaners containing chloride, chlorine bleach solutions, concentrated soaps, water with high salinity, or
hydrochloric acid, since they will cause corrosion or discoloration of the stainless-steel surface.
Do not use metal scrapers, sharp objects, steel wool, scouring pads, or abrasives on the unit.
Do not use a water jet to clean the surface.