Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Controls and Adjustments
- 1. Default Dip Switch Settings
- 2. Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 6. Bin Control Shutdown Delay, Agitation, and Ice Purge Timer (S1 dip switch 8)
- 7. Bin Control Shutdown Delay (S1 dip switch 9)
- 8. Factory Use (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
58
VIII. Technical Information
We reserve the right to make changes in specications and design without prior notice.
A. Specication & Performance Data Sheets
Note: The data not in bold should be used for reference only.
1. DCM-300BAH(-OS)
Specification Sheet
AC SUPPLY VOLTAGE 115-120/60/1
COMPRESSOR 115 V
6.0 RLA 29 LRA
GEAR MOTOR 120 V 1.45 FL
A
80 W
FAN MOTOR 115 V 0.8 FL
A
16 W
AGITATING MOTOR 115 V 0.9 FL
A
55 W
DISPENSING MOTOR 115 V 0.9 FL
A
55 W
OTHER 120 V 0.2 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
661
(
6.84
)
653 (4.88)
POTABLE WATER
29
(
12.5
)
40 (12.5)
gal./24HR (gal./100 lbs.)
BIN CONTROL SYSTEM Mechanical Bin Control (Proximity Switch)
REFRIGERANT CHARGE R-404A, 15.9 oz. (450 g)
Performance Data Shee
t
APPROXIMATE Ambient
ICE PRODUCTION Temp. (°F)
PER 24 HR. 70 321 146 307 139 291 132
80 277 125 263 119 249 113
90 237 107 232 105 214 97
lbs./day kg/da
y
100 203 92 193 87 181 82
APPROXIMATE ELECTRIC 70 653 -- 654 -- 655 --
CONSUMPTION 80 656 -- 658 -- 659 --
90 660 -- 661 -- 666 --
watts 100 671 -- 675 -- 680 --
APPROXIMATE WATER 70 40 152 38 145 36 138
CONSUMPTION PER 24 HR. 80 35 131 33 124 31 118
90 30 112 29 110 27 101
gal./day l/da
y
100 25 96 24 91 23 86
EVAPORATOR OUTLET TEMP. 70 19 -7 19 -7 19 -7
80 19 -7 23 -5 23 -5
90 23 -5 23 -5 25 -4
°F °C 100 25 -4 25 -4 25 -4
HEAD PRESSURE 70 200 14.1 200 14.1 200 14.1
80 237 16.6 237 16.6 237 16.6
90 273 19.2 273 19.2 273 19.2
PSIG kg/cmG 100 315 22.1 315 22.1 315 22.1
SUCTION PRESSURE 70 37 2.6 37 2.6 37 2.6
80 39 2.7 39 2.7 39 2.7
90 41 2.9 41 2.9 41 2.9
PSIG kg/cmG 100 45 3.2 45 3.2 45 3.2
TOTAL HEAT OF REJECTION
Water Temp. (°F)
3,500 BTU/h (AT 90°F /WT 70°F)
50 70 90
ENG F-013.0.1196