K1 Connector
#3 GM (P) or (DBU)
#2 115VAC Input (BR)
Drain Valve
#10 (W/DBU)
K6 Connector
Open
"SERVICE" Button
(Ice Purge Cycle Bypass)
Control Transformer 24VAC
Input #1 (W/R)
Compressor Control Relay Circuit
#5 (W/O) to #6 (W/O)
Relay De-Energized-Open-5VDC
Relay Energized-Closed-0VDC
High-Pressure Switch
#3 (Y) to #4 (Y)
Open-5VDC
Closed-0VDC
Control Switch
#1 (W/BK) to #2 (W/BK)
"ICE"-Open-5VDC
"DRAIN"-Closed-0VDC
"POWER OK" LED
Control Transformer 24VAC
Neutral #2 (LBU)
S1 Dip Switch
K9 Connector
K8 Connector
(24VAC and 5VDC)
K7 Connector
K2 Connector
Fig. 9b
K4 Pin #1
(5VDC Circuit Terminal)
Inlet Water Valve
#8 (O) or (W/BR)
Control Transformer
Input #9 (W/R) or (R)
Control Transformer
Input #7 (W/R) or (R)
5VDC
115 VAC
24VAC
5VDC
5VDC
115 VAC
24VAC
OS Water Dispense Common
#9 (BK) or (P)
Ice Dispense Common
#3 (W/BK) or (BR)
Water Dispense Signal
#8 (P), (BK), or (W)
Ice Dispense Signal
#2 (W) or (Y)
OS Ice Sensor
#1 (W/R) or (P)
OS Water Sensor
#7 (R)
24VAC Input
#5 (W/R) or (R)
115VAC Input
#3 (BR) or (BK)
Ice Dispense
Solenoid #2 (DBU) or (P)
115VAC Input
1 (BR) or (BK)
Dispense Water
Valve #6 (W/O)
LED Legend:
COMP-compressor
FLUSH (Drain)-drain valve
GM-gear motor
ICE-ice dispense motor
WTRDP-water dispense valve
WTRIN-inlet water valve
DRAIN
Upper Float Switch Signal #6 (R)
Open-5VDC to #5 black
Closed-0VDC to #5 black
Lower Float Switch Signal
#7 (BU) or (DBU)
Open-5VDC to #5 black
Closed-0VDC to #5 black
Compressor Relay
115VAC input (BR)
115VAC output (R)
Agitation GM
#4 (O) or (GY)
Float Switch Common
#5 (BK)
2A9093-01
Bin Control
#3 (GY) Common
#4 (GY) Signal
Open-5VDC
Closed-0VDC
2. Control Board Layout (Opti-Serv)
Control Board
Part Number 2A9093-01
Ice Dispense Signal (Portion)
#5 (DBU) or (W/O)
Note: Control Board layout is the same for 2A4296-01, 2A8054-01, and 2A9093-01.