Instruction Manual
Table Of Contents
6
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. DCM-300BAH(-OS)
Single Phase
Model Number DCM-300BAH(-OS)
AC Supply Voltage 115-120/60/1
Compressor 115V 6.0RLA 29.0LRA
Gear Motor 120V 1.45FLA 80W
Fan Motor 115V 0.8FLA 16W
Agitating Motor 115V 0.9FLA 55W
Dispensing Motor 115V 0.9FLA 55W
Other 120V 0.2A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
Design Pressure HI-460PSI LO-290PSI
Refrigerant 404A 15.9 OZ.
2. DCM-500B_H(-OS)
Single Phase
Model Number DCM-500BAH(-OS) DCM-500BWH(-OS)
AC Supply Voltage 115-120/60/1 115-120/60/1
Compressor 120V 7.5RLA 54.5LRA 120V 7.5RLA 54.5LRA
Gear Motor 120V 2.4FLA 1/4HP 120V 2.4FLA 1/4HP
Fan Motor 120V 1.0FLA 50W - - -
Agitating Motor 120V 0.9FLA 55W 120V 0.9FLA 55W
Dispensing Motor 120V 0.9FLA 55W 120V 0.9FLA 55W
Other 120V 0.2A 115V 0.2A
Maximum Fuse Size 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS
Design Pressure HI-460PSI LO-290PSI HI-460PSI LO-290PSI
Refrigerant 404A 1 LB 4.1 OZ. 404A 11.5 OZ.