Service Manual

Table Of Contents
37
4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The dispense mode switch must be in the "CONTINUOUS" position for this setting to
apply. The factory setting allows ice to be dispensed continuously on push button models
and for a maximum of 60 sec. on Opti-Serve models.
S1 Dip Switch Setting
Dispense Time
No. 5 No. 6
OFF OFF No Limit
ON OFF 20 Seconds
OFF ON 60 Seconds
ON ON No Limit
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set for mechanical bin control operation. No adjustment is
required. Inthe factory default position (S1 dip switch 7 in the off position), the gear
motor delay after the upper oat switch closes is 5 seconds. WARNING! Do not adjust
S1 dip switch 7 out of the factory default position. This dip switch must be left in
the factory default position or the appliance will not operate correctly.
S1 Dip Switch
Setting
Bin Control Application Gear Motor Delay
No. 7
OFF Mechanical Bin Control 5 seconds
ON
Infrared Sensor with
Mechanical Bin Control Backup
30 seconds
6. Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the mechanical bin control proximity switch opening and the control board
shutting off the appliance.
S1 Dip Switch
Setting
Bin Control #1
Shutdown Delay
No. 8
OFF 0.25 Seconds
ON 6.7 Seconds
7. Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.