6. Low Water Safety
Upper oat switch fails to close within 90 seconds after the lower oat switch opens, the
150 second shutdown sequence begins. The inlet water valve remains open until the
upper oat switch closes.
BK BLACK O ORANGE W/BK WHITE/BLACK
BR BROWN P PINK W/BR WHITE/BROWN
BU BLUE R RED W/BU WHITE/BLUE
DBU DARK BLUE V VIOLET W/O WHITE/ORANGE
GY GRAY W WHITE W/R WHITE/RED
LBU LIGHT BLUE Y YELLOW
WIRE COLOR CODE
(Control Board)
(Control Board)
DCM-500BAH-OS
DCM-500BWH-OS
DCM-500BAH
DCM-500BWH