29
5. Shutdown
The bin control switch is activated and a 150 second shutdown sequence begins. After
the bin control has been open for 90 seconds, the compressor and fan motor stop, the
agitating motor operates for 0.6 seconds, and 60 seconds later the gear motor stops.
BK BLACK O ORANGE W/BK WHITE/BLACK
BR BROWN P PINK W/BR WHITE/BROWN
BU BLUE R RED W/BU WHITE/BLUE
DBU DARK BLUE V VIOLET W/O WHITE/ORANGE
GY GRAY W WHITE W/R WHITE/RED
LBU LIGHT BLUE Y YELLOW
WIRE COLOR CODE
(Control Board)
(Control Board)
DCM-500BAH-OS
DCM-500BWH-OS
DCM-500BAH