Service Manual
ManualsBrandsHoshizaki ManualsCommercial Countertop Ice Makers and DispensersDCM-300BAH-OS 26" Opti-Serve Series Sanitary Cubelet Ice Machine and Dispenser with 321 lbs. Daily Ice Production, Built-In 40 lbs. Ice Storage, CleanCycle12, H-GUARD Plus, and Corrosion Resistant Stainless Steel Exterior: Stainless Steel
Table Of Contents
- Important Safety Information
- I. Specifications
- II. General Information
- III. Technical Information
- IV. Service Diagnosis
- V. Removal and Replacement of Components
- A. Service for Refrigerant Lines
- B. Important Notes for Component Replacement
- 1. Upper Bearing Wear Check
- 2. Removal and Replacement of Extruding Head
- 3. Removal and Replacement of Auger
- 4. Removal and Replacement of Evaporator
- 5. Removal and Replacement of Mechanical Seal and Lower Housing
- 6. Removal and Replacement of Gear Motor
- 7. Dispense Auger and Agitator
- 8. Dispense or Agitating Motor
- VI. Cleaning and Maintenance
- VII. Disposal
35
Ice Purge Cycle
1. Control Board a) No power to gear motor.
2. Gear Motor a) External protector (gear motor overload) open.
b) Internal protector open.
c) Motor winding open.
d) Mechanical failure.
3. Coupling a) Defective.
Freeze Cycle
1. Control Board a) Defective.
2. Compressor a) External protector open.
b) Motor winding open.
c) Capacitor defective.
d) Start relay defective.
e) Mechanical failure.
3. Fan Motor a) Motor winding or internal protector open.
b) Bearing worn out or locked rotor.
4. Evaporator a) Dirty.
b) Damaged or defective.
5. Thermostatic Expansion Valve
(TXV)
a) Bulb loose.
b) Operating erratically.
6. Refrigerant Charge a) Low.
7. Drain Valve a) Dirty, leaking by.
b) Defective coil.
8. Water System a) Water leaks.
Rell
1. Water Supply a) Off.
2. Float Switch
See "IV.E. Float Switch Check
and Cleaning."
a) Float does not move freely.
b) Defective.
3. Water Control Relay a) Energized(upperoatswitchstuckclosed).
b) Defective.
4. Inlet Water Valve a) Screen or orice clogged.
b) Coil winding open.
Shutdown
1. Bin Control a) Not enough ice in bin to trip actuator paddle.
b) Proximity switch defective.
c) Actuator paddle does not move freely.
2. Control Board a) Defective.