Service Manual
ManualsBrandsHoshizaki ManualsCommercial Countertop Ice Makers and DispensersDCM-300BAH-OS 26" Opti-Serve Series Sanitary Cubelet Ice Machine and Dispenser with 321 lbs. Daily Ice Production, Built-In 40 lbs. Ice Storage, CleanCycle12, H-GUARD Plus, and Corrosion Resistant Stainless Steel Exterior: Stainless Steel
Table Of Contents
- Important Safety Information
- I. Specifications
- II. General Information
- III. Technical Information
- IV. Service Diagnosis
- V. Removal and Replacement of Components
- A. Service for Refrigerant Lines
- B. Important Notes for Component Replacement
- 1. Upper Bearing Wear Check
- 2. Removal and Replacement of Extruding Head
- 3. Removal and Replacement of Auger
- 4. Removal and Replacement of Evaporator
- 5. Removal and Replacement of Mechanical Seal and Lower Housing
- 6. Removal and Replacement of Gear Motor
- 7. Dispense Auger and Agitator
- 8. Dispense or Agitating Motor
- VI. Cleaning and Maintenance
- VII. Disposal
30
8) Drain Cycle – "FLUSH" (drain) LED is on: 12-hr. DCT terminates or CS is moved
to "DRAIN" position. 150-sec. shutdown sequence starts. 90 seconds later, Comp
de-energizes and Comp LED turns off. 60 seconds after Comp de-energizes, GM
de-energizes and GM LED turns off. Drain cycle starts. "FLUSH" LED turns on and DV
energizes. DV de-energizes after 20minutes when drain cycle is initiated by 12-hr. DCT.
When the drain cycle is initiated by CS (manual drain), DV de-energizes when CS is
moved to "OFF" position or "ICE" position.
Push Button Model: "FLUSH" (drain) LED is on. Conrm 24VAC at CB K2 connector
pin #8 (LBU wire) (12-hr. DCT) to CB K4 connector pin #2 (LBU wire). If 24VAC is not
present, conrm 24VAC at CB K2 connector pin #7 (R wire) to CB K4 connector pin
#2 (LBU wire). If 24VAC is present on CB K4 connector pin #7 (R wire) and not on pin
#8(LBU wire), replace CB. If 24VAC is present, DV energizes and allows water from the
evaporator and reservoir to drain for 20 minutes.
Opti-Serve Model: "FLUSH" (drain) LED is on. Conrm 24VAC at CB K2 connector
pin #10(LBU wire) (12-hr. DCT) to CB K4 connector pin #2 (LBU wire). If 24VAC is not
present and "FLUSH" LED is on (CS in the "ICE" position), replace CB. If 24VAC is
present, DV energizes and allows water from the evaporator and reservoir to drain for
20 minutes.
Manual Drain: Move CS to the "DRAIN" position. Conrm 24VAC at CB K3 connector
pin #3 (DBU wire) to CB K4 connector pin #2 (LBU wire). If 24VAC is not present,
replace CB. If 24VAC is present, check CS (LBU wire) to CB K4 connector pin
#2(LBUwire). If 24VAC is not present, replace CS. If 24VAC is present, DV energizes
and allows water from the evaporator and reservoir to drain.
9) Shutdown – When BC actuator paddle is activated, BC proximity switch opens, 5VDC
is interrupted at CB K4 connector pin #3 (GY wire) and #4 (V wire). 150-sec. shutdown
sequence starts. 90 seconds after BC opens, Comp de-energizes, 60seconds later,
GM de-energizes. If 5VDC is present from CB K4 connector pin #3 (GY wire) to CB
connector pin #4(Vwire), and Comp or GM does not de-energize, replace CB.
Legend: AM–agitating motor; BC–bin control; CB–control board; Comp–compressor;
CS–control switch; CT–control transformer; DCT–drain cycle timer (12-hr. timer);
DispWV–dispense water valve; DM–dispense motor; DMS–dispense mode switch
("CONTINUOUS," or "PORTION"); DS–dispense solenoid; DVT–drain valve timer
(20-min. timer); FM–fan motor; GM–gear motor; GMPR–gear motor protect relay;
LF/S–loweroatswitch;UF/S–upperoatswitch;WCR–water control relay;
WV–inlet water valve