52
8) Remove the spout cover, ice dispense spout, and water dispense nozzle. See Fig. 7.
9) Immerse the agitator, dispense auger, and parts removed in steps 5 through 8 in the
cleaning solution and then in the sanitizing solution for 15 minutes each. Rinse the parts
thoroughly with clean water. On Opti-Serve models (-OS), wipe the optical sensors with
cleaning solution and then with a clean, damp cloth.
10) Wipe the shutter located above the ice dispense spout thoroughly with a clean cloth.
11) Reassemble the bin control assembly and replace all parts in the reverse order of which
they were removed.
12) Pour warm water into the storage bin and melt any remaining ice. Clean the storage bin
liner and the storage bin cover using a neutral cleaner. Rinse thoroughly after cleaning.
Replace the storage bin cover in its correct position.
13) Move the power switch to the "ON" position, then replace the panels in their correct
positions. Turn on the power supply, then move the control switch to the "ICE" position
to start the automatic icemaking process.
Fig. 7
Spout Cover
Ice Dispense Spout
Water Dispense Nozzle