Service Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- II. General Information
- III. Technical Information
- IV. Service Diagnosis
- V. Removal and Replacement of Components
- A. Service for Refrigerant Lines
- B. Important Notes for Component Replacement
- 1. Upper Bearing Wear Check
- 2. Removal and Replacement of Extruding Head
- 3. Removal and Replacement of Auger
- 4. Removal and Replacement of Evaporator
- 5. Removal and Replacement of Mechanical Seal and Lower Housing
- 6. Removal and Replacement of Gear Motor
- 7. Dispense Auger and Agitator
- 8. Dispense or Agitating Motor
- VI. Cleaning and Maintenance
- VII. Disposal
16
3. Dispense Mode Switch
The dispense mode switch has 2 positions, "CONTINUOUS" and "PORTION."
a) CONTINUOUS
When the dispense mode switch is in the "CONTINUOUS" position, ice dispenses
continuously for a maximum of 60 seconds per activation.
b) PORTION
When the dispense mode switch is in the "PORTION" position, ice dispenses for the
amount of time determined by the ice dispense time setting.
The ice dispense time control is located on the control board. The dial indicates
dispense time in seconds and is adjustable between 0.6 and 20 seconds. When
shipped, the ice dispense time control is set to the minimum dispense time of 0.6 sec.
(approximately 0.72 oz.).
2. Control Switch
The control switch is a double-pole double-throw switch with 3 positions, "ICE," "OFF,"
and "DRAIN."
a) ICE
When the control switch is in the "ICE" position, the control switch directs 5VDC from
control board K4 connector pin #3 to control board K4 connector pin #4. When the
control board receives 5VDC on K4 connector pin #4, the icemaking process starts.
b) DRAIN
When the control switch is in the "DRAIN" position, the control switch directs
24VAC power supply to the drain valve and breaks the 5VDC to the control board
K4connector pin #4.
CONTROL
DISPENSE MODE
4A1038-014
ICE
OFF
DRAIN
PORTION
CONTINUOUS
CONTROL
DISPENSE MODE
4A1038-014
ICE
OFF
DRAIN
PORTION
CONTINUOUS
Ice Dispense Time Control