Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 7. Bin Control Shutdown Delay (S1 dip switch 9)
- 8. Audible Alarm Silencer (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
8
II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
Sequence Flow Chart
DCM-271B_H(-OS)
1-in-1 drain cycle. DV energizes for 2 seconds every hour
(S1 Dip Switch 4).
Does not affect operation.
GM energized
FM energized
UFS open
LFS open
FT starts (90 sec.)
FZT terminated
WV energized
Comp energized
FM energized
GM energized
1. Startup
2. Ice Purge Cycle
Comp energized
FM energized
GM energized
Power Switch "ON"
Control Switch in "ICE"
"POWER OK" LED on
1. Fill Cycle
3. Freeze Cycle
LFS closed
UFS closed
FZT starts (30
min.)
FT terminated
WV de-energized
Comp energized
FM energized
GM energized
Low Water Safety
Purge Timer
1-beep alarm sounds
PT starts
UFS open
Comp de-energized
FM energized
GM energized
WV energized
Legend:
BC-bin control
Comp-compressor
DC-drain cycle
DT-drain timer
DV-drain valve
FM-fan motor
FT-๎ll timer (low water safety)
FZT-freeze timer
GM-gear motor
LFS-lower ๎oat switch
PT-purge timer
UFS-upper ๎oat switch
WV-inlet water valve
4. 1-in-12 Drain Cycle - The factory default is 1-in-1 drain cycle.
IMPORTANT! Do not adjust for 1-in-12 drain cycle sequence on
this model.
Re๎ll
Maximum
90 seconds
90 sec. FT exceeded
90 sec. PT starts and
1-beep alarm sounds
Low Water Safety
Shutdown
90 sec. PT terminates
appliance shuts down and
1-beep alarm continues.
When UFS closes, alarm
resets and 2. Ice Purge
Cycle starts.
1-beep alarm continues
WV energized
FM de-energized
GM de-energized
90 seconds
FT
exceeded
PT
terminates
To bypass, press the
"SERVICE" button after
GM starts.
1-min.
5 sec.
Maximum
90 seconds
LFS closed
UFS closed
FT terminates
FZT starts
WV de-energized
WV energized
FT starts (90 sec.)
If Fill > 90 sec. FT
1-beep alarm sounds
WV energized
When UFS closes
alarm resets and
2. Ice Purge Cycle starts.
to "2. Ice Purge Cycle" above if UFS closed.
to "1. Fill Cycle" above if UFS open.
1. Bin Full
FM energized
GM energized
Comp de-energized
FM de-energized
GM de-energized
3. Icemaker Off
BC open
Comp energized
FM energized
GM energized
2. Ice Purge Cycle
4. Icemaker
Restart
150-sec. Shutdown Sequence
BC closed
2. Bin Control
Shutdown & Restart
BC open
(BC large balance
plate engaged)
90 sec. 60 sec.