Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 7. Bin Control Shutdown Delay (S1 dip switch 9)
- 8. Audible Alarm Silencer (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
36
4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
The factory setting allows ice to be dispensed continuously for 20 sec. The DCM-271BAH
may be adjusted to other dispense time options.
NOTICE! On DCM-271BAH-OS, do not adjust S1 dip switch 5 & 6 out of the factory
default position.
S1 Dip Switch Setting
Dispense Time
No. 5 No. 6
OFF OFF No Limit
ON OFF 20 Seconds
OFF ON 60 Seconds
ON ON No Limit
Note: The ice dispense solenoid has an internal overload protector. When set to "No
Limit" the internal protector may open if ice dispense solenoid is energized longer than
3to 4 min. at one time.
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set with mechanical bin control operation. No adjustment is
required. Inthe factory default position (S1 dip switch 7 in the off position), the gear
motor delay after the upper oat switch closes is 5 seconds. WARNING! Do not adjust
S1 dip switch 7 out of the factory default position. This dip switch must be left in
the factory default position or the appliance will not operate correctly.
S1 Dip Switch Setting
Bin Control Application Gear Motor Delay
No. 7
OFF Bin Control (Mechanical) 5 seconds
ON
Bin Control (Infrared Sensor) with optional
Mechanical Bin Control Backup
30 seconds
6. Bin Control Shutdown Delay, Agitation, and Ice Purge Timer (S1 dip switch 8)
The shutdown delay is the time between the bin control micro-switch opening and the
control board shutting down the appliance. WARNING! Do not adjust S1 dip switch
8 out of the factory default position. This dip switch must be left in the factory
default position or the appliance will not operate correctly.
S1 Dip Switch Setting
Storage Bin Periodic Agitation Ice Purge Timer
No. 8
OFF 2 Seconds 60 Seconds (1 min.)
ON No Agitation 300 Seconds (5 min.)