Service Manual

31
A. Control Board Layout
1. DCM-271BAH
a) Control Board
Control Transformer
Input #7 (W/R)
Drain Valve
#10 (W/DBU)
K6 Connector
Open
"SERVICE" Button
(Ice Purge Cycle Bypass)
Control Transformer
24VAC Input #1 (W/R)
Compressor Control Relay Circuit
#5 (W/O) to #6 (W/O)
Relay De-Energized-Open-5VDC
Relay Energized-Closed-0VDC
High-Pressure Switch
#3 (Y) to #4 (Y)
Open-5VDC
Closed-0VDC
Control Switch
#1 (W/BK) to #2 (W/BK)
"ICE"-Open-5VDC
"DRAIN"-Closed-0VDC
Control Transformer
24VAC Neutral #2 (LBU)
Float Switch Common
#5 (BK)
K9 Connector
K7 Connector
K2 Connector
Fig. 9a
K1 Connector
#3 GM (P)
#2 115VAC
Input (BK)
Inlet Water Valve
#8 (O)
Control Transformer
Input #9 (W/R)
5VDC
115 VAC
24VAC
5VDC
5VDC
115 VAC
24VAC
Upper or Lower Ice
Dispense Signal
#2 (Y)
Upper Water/Ice
Dispense Common
#3 (W/BK)
Upper or Lower Water
Dispense Signal
#8 (P)
24VAC Input
#5 (W/R)
115VAC Input
#3 (BK)
Agitation GM
#4 (Y)
115VAC Input
#1 (BK)
Dispense Water
Valve #6 (W/O)
LED Legend:
COMP-compressor
FLUSH (DRAIN)-drain valve
GM-gear motor
ICE-dispense motor
WTRDP-water dispense valve
WTRIN-inlet water valve
DRAIN
Compressor Relay
115VAC input (BK)
115VAC output (R)
Bin Control
#3 (GY) Common
#4 (GY) Signal
Open-5VDC
Closed-0VDC
"POWER OK" LED
S1 Dip Switch
K8 Connector
(24VAC and 5VDC)
Ice Dispense
Solenoid #2 (DBU)
Upper Float Switch Signal
#6 (R)
Open-5VDC to #5 black
Closed-0VDC to #5 black
Lower Float Switch Signal
#7 (BU)
Open-5VDC to #5 black
Closed-0VDC to #5 black
2A9093-01
K4 Pin #1
(5VDC Circuit Terminal)
Control Board
Part Number 2A9093-01
Lower Water/Ice
Dispense Common
#9 (BK)
Lower Dispense
Button LED Power
#7 (R)
Upper Dispense
Button LED Power
#1 (W/R)