Water Dispense-Push Button
1. Power Supply a) Off, blown fuse, or tripped breaker.
2. Control Board
See "II.C. Control Board Check"
a) No power from control board to dispense board (5VDC) or not
reading signal.
b) No power to dispense water valve (24VAC).
3. Dispense Board a) Defective.
4. Water Dispense Valve a) Water supply turned off.
b) Defective.
Water Dispense-Opti-Serve
1. Power Supply a) Off, blown fuse, or tripped breaker.
2. Control Board
See "II.C. Control Board Check"
a) No power from control board to OS sensor (5VDC) or not reading
signal.
b) No power to water dispense valve (24VAC).
3. OS Sensor (infrared) a) Defective.
4. Water Dispense Valve a) Water supply turned off.
b) Defective.