Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 7. Bin Control Shutdown Delay (S1 dip switch 9)
- 8. Audible Alarm Silencer (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
17
(2) 5VDC CB K8 Connector: See Fig. 2.
a) Bin Control (BC)
CB K8 pin #3 (GY) and pin #4 (GY): When BC is closed (icemaking), 5VDC is present
between CB K8 pin #3 (GY) and pin #4 (GY) to CB red K4 pin #1 (pin closest to CB
black K3). If 5VDC is not present on either pin, replace CB. If 5VDC is present on pin
#3 (GY) and not on pin #4 (GY), BC is open. See "II.D. Bin Control Check."
b) Float Switch (FS): Upper (UFS) and Lower (LFS):
CB K8 pin #5 common (BK), pin #6 UFS (R), and pin #7 LFS (BU): 5VDC is present
between CB K8 pin #5 common (BK) and CB red K4 pin #1 (pin closest to CB
black K3) at all times. If 5VDC is not present, replace CB. For further oat switch
diagnostics, see "II.E. Float Switch Check and Cleaning."
5VDC CB K8 Connector
Component Pin # (Wire Color)
Bin Control (BC) #3 (GY) and #4 (GY)
Float Switch (FS) Common #5 (BK) Common
Upper Float Switch (UFS) #6 (R)
Lower Float Switch (LFS) #7 (BU)
Fig. 2
Multimeter
5VDC
Control Board K8 Connector
Bin Control (GY)
Upper Float Switch (UFS) (R)
Float Switch (FS) Common (BK)
Lower Float Switch (LFS) (BU)
Red test lead
to CB red
K4 pin #1 (pin
closest to CB
black K3)
Red Test Lead
Black Test Lead