Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 7. Bin Control Shutdown Delay (S1 dip switch 9) (F-C CB Only)
- 8. Factory Use (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
35
C. Settings and Adjustments
1. Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
Dip Switch No.
Control Board & Aux.
Code Revision
1 2 3 4 5 6 7 8 9 10
DCM-270BAH(-OS)
F-A: E-0 (G) and Earlier OFF OFF OFF OFF OFF OFF OFF ON OFF OFF
F-A: E-0 (H) to F-1 OFF OFF OFF OFF ON OFF OFF ON OFF OFF
F-C: F-1 and Later OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
2A4296-01: F-A Control Board
2A8054-01: F-C Control Board
Bin Control Shutdown Delay (infrared sensor)
Continuous Dispensing Timer
(Do not adjust on DCM-270BAH-OS)
Drain Frequency Control
Bin Control Selector
Bin Control Shutdown Delay (mechanical) and Periodic Agitation
of Storage Bin
Normally off (factory use)
2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
NOTICE
Do not adjust. Setting not used on this model. When dip switch 7 is off, dip switch
1, 2, and 3 are ignored.
Factory set. DCM-270BAH(-OS) does not use a bin control with an infrared sensor.
The appliance uses a bin control with a mechanical micro-switch for ice level control.
3. Drain Frequency Control (S1 dip switch 4)
The appliance is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the "OFF" position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process. NOTICE! Do not adjust S1 dip
switch 4 out of the factory default position. This dip switch must be left in the
factory default position or the appliance will not operate correctly.
S1 Dip Switch Setting
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1) 1 Hour 2 Seconds
ON (1-in-12) 11 Hours 45 Minutes 10 Minutes