Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
- 3. Drain Frequency Control (S1 dip switch 4)
- 4. Continuous Dispensing Timer (S1 dip switch 5 & 6)
- 5. Bin Control Selector (S1 dip switch 7)
- 7. Bin Control Shutdown Delay (S1 dip switch 9) (F-C CB Only)
- 8. Factory Use (S1 Dip Switch 10)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
15
1) Startup-"POWER OK" LED on: Move control switch to "ICE" position, then move
power switch to "ON" position. "POWER OK" LED turns on. "POWER" LED remains on
unless power supply is interrupted. Diagnosis: Checkthat "POWER OK" LED is on.
If not, check for proper 115VAC supply voltage to CT (main breaker or fuse and power
switch). Next, check for proper 24VAC output from CT. Next, check that 1A fuse is good.
Check for 24VAC from CB K8connector pin #1 (W/R) to CB K8 connector pin #2(LBU).
If24VAC is present and "POWER OK" LED is off, replace CB.
2) 5VDC Output Checks: There are seven 5VDC circuits on the appliance.
a) 3 circuits at CB K9 connector: Control switch "DRAIN" position, high-pressure switch
(HPS), and compressor control relay (CCR).
b) 2 circuits at CB K8 connector: Bincontrol (BC) and oat switch (FS upper and
lower).
c) 2 circuits at CB K7 connector: Ice dispense (push button, and OS sensor), and water
dispense (push button and OS sensor).
2a) 5VDC CB K9 Connector: See Fig. 1.
5VDC CB K9 Connector
Component Pin # (Wire Color)
Control Switch "DRAIN" Position #1 (W/BK) and #2 (W/BK)
High-Pressure Switch (HPS) #3 (Y) and #4 (Y)
Compressor Control Relay (CCR)
(CCR relay terminals #3 W/O and #5 W/O)
#5 (W/O) and #6 (W/O)
Red positive test lead to
redK4 connector pin closest
to black K3 connector
Fig. 1
Control Board K9 Connector
Red Positive
Test Lead
Black Negative
Test Lead
Multimeter
5VDC
"DRAIN" Position on
Control Switch
(W/BK)
High-Pressure Switch (HPS) (Y)
Compressor Control Relay (CCR)
CCR Terminals #3 (W/O)
and #5 (W/O)