II. Sequence of Operation and Service Diagnosis
A. Sequence of Operation Flow Chart
"F-A" & "F-C" Control Board Sequence Flow Chart
DCM-270B_H(-OS)
1-in-1 drain cycle. DV energizes for 2 seconds every hour
(S1 Dip Switch 4).
Does not affect operation.
GM energized
UFS open
LFS open
FT starts (90 sec.)
WV energized
Comp energized
FM energized
GM energized
1. Startup
2. Ice Purge Cycle
Comp energized
FM energized
GM energized
Power Switch "ON"
Control Switch in "ICE"
"POWER OK" LED on
1. Fill Cycle
3. Freeze Cycle
LFS closed
UFS closed
FT terminates
WV de-energized
Comp energized
FM energized
GM energized
Low Water Safety
1-beep alarm sounds
PT starts
UFS open
Comp de-energized
FM de-energized
WV energized
GM energized
Legend:
BC-bin control
Comp-compressor
DC-drain cycle
DT-drain timer
DV-drain valve
FM-fan motor
FT-๎˜Ÿll timer (low water safety)
GM-gear motor
LFS-lower ๎˜oat switch
PT-purge timer
UFS-upper ๎˜oat switch
WV-inlet water valve
4. 1-in-12 Drain Cycle - The factory default is 1-in-1 drain cycle.
IMPORTANT! Do not adjust for 1-in-12 drain cycle sequence on
this model.
Re๎˜Ÿll
Maximum
90 seconds
90 sec. FT exceeded
1-beep alarm sounds
90 sec. PT starts
When UFS closes,
alarm resets and
2. Ice Purge Cycle
starts.
1-beep alarm continues
WV energized
GM de-energized
90 seconds
FT exceeded
PT terminates
To bypass, press the
"SERVICE" button after
GM starts.
*1-min. or 5-min.
5 sec.
Maximum
90 seconds
LFS closed
UFS closed
FT terminates
WV de-energized
WV energized
FT starts (90 sec.)
If Fill > 90 sec. FT
1-beep alarm sounds
WV energized
When UFS closes
alarm resets and
2. Ice Purge Cycle starts.
to "2. Ice Purge Cycle" above if UFS closed.
to "1. Fill Cycle" above if UFS open.
1. Bin Full
GM energized
Comp de-energized
FM de-energized
GM de-energized
3. Icemaker Off
BC open
Comp energized
FM energized
GM energized
2. Ice Purge Cycle
4. Icemaker
Restart
150-sec. Shutdown Sequence
BC closed
BC open
(BC large balance
plate engaged)
2. Icemaker Off
2. Bin Control
Shutdown & Restart
1. Bin Full
3. Icemaker Restart
All Components de-energized
Ice level lowered
6 to 10 sec.
BC closed
(BC large balance plate disengaged)
A. "F-A" E-0 (G) and
Earlier Dip Switch
8 "ON"
B. "F-A" E-0 (H) and Later
Dip Switch 8 "OFF"
C. "F-C" Dip Switch
8 and 9 "OFF"
to "2. Ice Purge Cycle" above if UFS closed.
to "1. Fill Cycle" above if UFS open.
BC open
(BC large balance
plate engaged)
90 sec. 60 sec.
*"F-A" E-0 (G) and Earlier dip switch 8 on - 5 min.
*"F-A" E-0 (H) and Later and "F-C" dip switch 8 off - 1 min. and a 2-second periodic agitation was added to occur every 90 min.